Operating Instructions
Operating & Maintenance Manual
41
This unit is equipped with on-board fuel tanks with a total capacity of 230 gallons which
provides 10 hours of full load operation.
Compressor Mounting
Portable compressors, which are modified to remove the running gear and mount the machine
direct to trailers, truck beds or frames, etc. may experience failure of the enclosure, frame,
and/or other components. It is necessary to isolate the compressor package from the carrier
base with a flexible mounting system. Such a system must also prevent detachment of the
package from the carrier base in the event the isolators fail. Contact your Portable Power
representative for flexible mounting kits.
Warranty does not cover failures attributable to mounting of the compressor package to the
carrier base unless it is a Portable Power provided system.
WARNING
!
Do not connect the air discharge on this unit onto a common header with
any other unit of any description, or any other source of compressed air,
without first making sure a check-valve is used between the header and
the unit. If this unit is connected in parallel with another unit of higher
discharge pressure and capacity, a safety hazard could occur in a back-
flow condition.
WARNING
!
Unrestricted air flow from a hose will result in a whipping motion of the
hose which can cause serious injury or death. A safety device must be
attached to the hose at the source of supply to reduce pressure in case
of hose failure or other sudden pressure release. Reference: OSHA
regulation 29 CFR Section 1926.302 (b).
Air hose restraining cable installation:
Secure hose restraining cable at each end to prevent accidental hose whipping. At the
machine-side of the air hose, install and secure one end of the hose restraining cable on the
3” nipple on the inlet side of the 3” service valve. Install the other end of the hose restraining
cable over the main hose connector.
Install suitable 3” air hose between service valve on unit and point of air use. The air hose must
be rated for outdoor use and for pressurized air service. Minimum rating is 250°F (121°C) and
200 psig (HP) or 425 psig (XHP).
Содержание 10/370
Страница 2: ...2...
Страница 6: ...6...
Страница 7: ...7 Foreword...
Страница 8: ...Operating Maintenance Manual Foreword 8 Add in PDF Page for CE Mark...
Страница 11: ...11 Safety...
Страница 19: ...Safety Operating Maintenance Manual 19...
Страница 20: ...Operating Maintenance Manual Safety 20...
Страница 21: ...Safety Operating Maintenance Manual 21...
Страница 23: ...Safety Operating Maintenance Manual 23...
Страница 26: ...Operating Maintenance Manual Safety 26...
Страница 27: ...27 Noise Emission...
Страница 33: ...33 General Data...
Страница 36: ...36...
Страница 37: ...37 Operating Instructions...
Страница 52: ...52...
Страница 53: ...53 Maintenance...
Страница 66: ...66...
Страница 67: ...67 Lubrication...
Страница 71: ...71 Troubleshooting...
Страница 82: ...82...
Страница 83: ...83 Electrical...
Страница 88: ...88...
Страница 89: ...89 Electrical Schematics...
Страница 90: ...Operating Maintenance Manual Electrical Schematics 90...
Страница 91: ...Electrical Schematics Operating Maintenance Manual 91...
Страница 92: ...Operating Maintenance Manual Electrical Schematics 92...
Страница 93: ...Electrical Schematics Operating Maintenance Manual 93...
Страница 94: ...94...