DOOR OPERATION
12
I
USER MANUAL
ADDITIONAL ENTRIES
Additional entries are sorted by the following priorities (from highest to lowest): STOP, LOCK, OPEN,
AUTO SUMMER, AUTO WINTER, EXIT SUMMER . If several additional entries are activated, the system
switches to the operating mode with the highest priority .
IN CASE OF POWER FAILURE
COM21 is connected to additional entries . In case several additional entries are active, the
system will use the one with the highest priority .
Connection on door controller
X8-1
X8-2
X8-3
X8-4
X8-6
X8-7
NO contact
NO contact
NO contact
NC or NO contact
LOCK
NO contact
OPEN
AUTO SUMMER
AUTO WINTER
X8-5
NO contact
EXIT SUMMER
GROUND
STOP
Automatic sliding doors product line 300 can be equipped with a battery support in case of power supply
shortage due to a power cut in the electric power network . In such a case the LED diode LED1 in the EC4
door controller switches off, the doors open and remain still in open position after the power failure . The
system automatically switches off when the battery voltage drops to a certain limit .
The system can be re-activated by holding the WAKE BUTTON on the mode selector for 1 second or
triggering the input “open once” (X7-1) on the door controller EC4 . The operating mode can be changed
after the system is re-activated by the above-described procedure . The system will automatically shut
down again if the main power supply stays off-line . The battery unit can be depleted in the case that main
power supply failure lasts longer . The system automatically switches to the main power supply source
when the main power supply re-establishes . In operation mode “CLOSED” the doors will close, even if
there is no electric power network .
The battery unit can be stored or stay DISCONNECTED from door controller for a maximum of
6 months, otherwise it needs to be replaced .
If the doors are not working for more than 1 week, the batteries need to be disconnected from
door controller .