SET ACCESS CONFIGURATION 

• Card or PIN (Default): The User must present a valid card/fob to the K401-E or enter their PIN code 
followed by the # key, in order to be granted access 
• Card + PIN: The User must first present a valid card/fob to the K401-E and then enter their PIN code 
followed by the # key, in order to be granted access 
 

Programming Step 

Keystroke Combination 

1. Enter Program Mode 

(Master Code) # 

2.

 

Card or PIN   

     Relay 1 
     Relay 2 
 
3. Card + PIN 
      Relay 1 
     Relay 2 

(Default) 

4 1 0 #   
4 2 0 # 
 
 
4 1 1 #   
4 2 1 # 

4. Exit Program Mode 

User Settings

 

To enter the programming mode    *    Master code    #   

To exit from the programming 
mode 

  *   

Note that to undertake the follow ing programming, the Master PIN must be entered 

Note: 
When adding users, if the card/fob or Pin user has been enrolled already, you can not add it again on the 
same relay, or the device will give a bleep as an error. It is ok to enroll the same card/fob or PIN for both 
relay outputs 

 

Factory default setting: Card or PIN mode   

To set users for Relay 1.    4      1      0      #   

To add PIN users 

1    User ID number    #    PIN #   

The ID number is any number from 1-1000 

The PIN is any 4-6  digits between 0000-999999 with the exception of 
1234 which is reserved. Users can be added continuously without exiting 
programming mode as follows: 

1    User ID no 1 #    PIN # User ID no 2 #    PIN # 

To delete PIN users 
 

3    User ID number    #   

Users can be deleted continuously without exiting programming mode 

To change the PIN of a PIN user 

(Note: This step must be done out of 
programming mode) 

  *    ID number #    Old PIN #    New PIN #    Repeat new PIN # 

ACCESS 

SECURITY 

PRODUCTS 

LTD

Содержание KP-401-EX

Страница 1: ...KP 401 EX External Stand Alone Keypad Proximity Card Reader User Manual A C C E S S S E C U R I T Y P R O D U C T S L T D...

Страница 2: ...K401 E has many extra features including block enrollment anti tamper alarm backlit keypad buttons These features make the K401 E an ideal choice for door access not only for small shops and domestic...

Страница 3: ...d Proximity Card 25mm 35mm Wiring Connections Electric Lock Exit Button DOTL External Alarm Door Bell Relay Adjustable Relay Output Time Adjustable Alarm Output Time Lock Output Load Alarm Output Load...

Страница 4: ...ed Power Input Black AC DC 12 24V DC 12 18V AC Regulated Power Input Grey Black GND Negative Pole Blue NO1 Normally Open Relay 1 output White COM1 Common Connection for Relay 1 Output Green NC1 Normal...

Страница 5: ...ontroller using Normally Open contact Comments Relay 2 can be used to operate a doorbell if there is no need to operate a second door The wiring to connect the doorbell is via NO2 and COM2 Press the K...

Страница 6: ...rd to allow rapid card enrollment They are for Relay 1 only Anti Tamper Alarm The K401 E uses an LDR light dependent resistor as an anti tamper alarm If the keypad facia is removed the tamper alarm wi...

Страница 7: ...ered Note When adding users if the card fob or Pin user has been enrolled already you can not add it again on the same relay or the device will give a bleep as an error It is ok to enroll the same car...

Страница 8: ...o delete Card users by cards Note Users can be deleted continuously without exiting programming mode 3 Read Card The device can automatically identify the card of relay 1 or relay 2 To delete Card use...

Страница 9: ...programming mode so the user can undertake this themselves ID number Old PIN New PIN New PIN To delete a Card and PIN user just delete the card 3 Read Card or 3 User ID To set users for relay 2 4 2 1...

Страница 10: ...eriod either the keypad will lockout for 10 minutes or the alarm will operate for 10 minutes depending on the option selected below Normal status No keypad lockout or alarm 7 0 Default Keypad Lockout...

Страница 11: ...ave been lost 1 Power down the K401 E 2 Press the Star button and hold at the same time power up the keypad 3 Release the button and wait until the amber LED shines Parts 4 5 must be undertaken within...

Страница 12: ...ay 1 ON Short Single Bleep Entry Granted for Relay 2 ON Alarm Mode Engaged Flashing Alarm K401 E Simplified Instruction Function Description Operation Enter the Programming Mode Master Code 666666 is...

Отзывы: