![Doorentryonline KP-401-EX Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/doorentryonline/kp-401-ex/kp-401-ex_card-readre_2521169011.webp)
Others
Using Master Cards
Using Master Card
(It is only available for relay 1)
Add a User Card
1. (Read Master Add Card)
2. (Read User Card)
Repeat Step 2 for additional user cards
3. (Read Master Add Card)
Delete a User Card
1. (Read Master Delete Card)
2. (Read User Card)
Repeat Step 2 for additional user cards
3. (Read Master Delete Card)
Reset to Factory Default:
This will reset the K401-E to the factory default but all card/PIN information will still be retained. This will also
require reprogramming of the Master Add and Delete Cards.
NOTE: This is useful if the original
Master Add
and Delete Cards have been lost
1. Power down the K401-E
2. Press the * (Star) button and hold, at the same time power up the keypad
3. Release the button and wait until the amber LED shines
(Parts 4 & 5 must be undertaken w ithin 10 seconds)
4. Present any 125KHz proximity EM card or the Master Add Card (provided) to the K401-E. This card is now
the Master Add Card
5. Present any 125KHz proximity EM card or the Master Delete Card (provided) to the K401-E. This card is now
the Master Delete Card
When the red LED begins to blink, the K401-E has been successfully reset
Erase all Users
This will delete ALL User data for relay 1 or relay 2 as per below
1. Enter Program Mode: *(Master Code)#
2. Enter 30000# (for relay 1) Or 90000 # (for relay 2)
3. Exit: *
All configuration data is retained
ACCESS
SECURITY
PRODUCTS
LTD