Cable Requirements

The maximum distance of the wiring is limited in the DT system. Using different cables may also 
affect the maximum distance which the system can reach. 

Specification

•   Power Supply: DC 24V

•   Power Consumption: Standby 60mA; 

W

orking status 200mA

•   Lock Power Supply:12Vdc, 300mA (Internal Power)

•   Working Temperature: -10ºC ~ +45ºC

•   Wiring: 2 wires, non-polarity

•   Dimension:137(H) x 49(W) x 28(D)mm

Precautions

•  Please clean the unit with a soft cotton cloth, don't use organic impregnated or chemical cleaning 

agents. 

If necessary, please use a small amount of pure water or diluted soap water to clean the unit.

•  The unit is weather resistant, however do not spray high pressure water on the access control keypad 

directly. Excessive moisture may cause problems with the unit.

•  You must use the right adaptor which is supplied by the manufacture or approved by the manufacture.

•  Pay attention to the high voltage inside the products, please refer service only to a trained and qualified 

professional.

Cable Usage

A

B

C

Twisted cable 2x0.75 mm

2

60

60

30

80

80

40

Twisted cable 2x1 mm

2

Cable Usage

A

B

C

Twisted cable 2x1 mm

2

70

30

20

70

50

30

Twisted cable 2x1.5 mm

2

1 2

3 4 5

6

ON

1 2

3 4 5

6

ON

1 2

3 4 5

6

ON

1 2

3 4 5

6

ON

1 2

3 4 5

6

ON

1 2

3 4 5

6

ON

1 2

3 4 5

6

ON

1 2

3 4 5

6

ON

1 2

3 4 5

6

ON

1 2

3 4 5

6

ON

1 2

3 4 5

6

ON

1 2

3 4 5

6

ON

1 2

3 4 5

6

ON

1 2

3 4 5

6

ON

1 2

3 4 5

6

ON

1 2

3 4 5

6

ON

The farest monitor

B

A

C

 DBC4S

monitor

monitor

monitor

with two or four monitors

AC~

DPS & PS5

-9-

Doorentryonline 

Ltd

Содержание DT595A

Страница 1: ...DT595A USER MANUAL 2 Wire Audio Entry System Read this manual carefully before using the product and keep it safe for future use D o o r e n t r y o n l i n e L t d...

Страница 2: ...be connected Please refer to DIP Switch Settings for additional door panels SPK adjust to adjust the talk volume PROG button reserved CALL button press to call the user 4P terminal to update software...

Страница 3: ...o fix the back panel and rain cover to the wall then connect the cable correctly 2 Attach the front panel to the back panel then use the screw to fix it Wiring and Connection Basic one to one connecti...

Страница 4: ...L2 PL S1 S2 S L1 L2 PL S1 S2 S 1 2 ON 1 2 ON 1 2 ON 1 2 ON 1 Panel DIP on off off ID 00 ID 10 ID 01 ID 11 2 Panel 3 Panel 4 Panel DBC4S A B C D OFF ON Impedance switch Code 0 DIP 6 off 1 2 3 4 5 6 ON...

Страница 5: ...e 4 DIP 6 on 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON Code 3 DIP 6 on Code 1 DIP 6 on 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON Code 2 DIP 6 on Code 0 DIP 6 on OFF ON OFF ON monitor 1 monitor 3 monitor 5 monitor 7 monitor 8...

Страница 6: ...LOCK Jumper position in Connect one lock 2 3 Bus PL S2 S1 S1 Note 1 The external power supply must be used according to the lock 2 The jumper must be taken off before connecting 3 Setup the Unlock Mod...

Страница 7: ...nstallation There are 6 bits in total The DIP switches are used to configure the user code for Monitors Bit 6 is an video impedance match switch which have to be set to ON if match the impedance other...

Страница 8: ...se use a small amount of pure water or diluted soap water to clean the unit The unit is weather resistant however do not spray high pressure water on the access control keypad directly Excessive moist...

Страница 9: ...y also affect the maximum distance which the system can reach Cable Usage A B C Twisted cable 2x0 75 mm2 60 60 30 80 80 40 Twisted cable 2x1 mm2 Cable Usage A B C Twisted cable 2x1 mm2 70 30 20 70 50...

Отзывы: