background image

Multi Door Panel Connection

Multi Monitor/Handset Connection

Basic IN-OUT wiring mode

Multi Handset with DBC4S 4 way branch connector

BUS (Blue&Green);

   S2+(Red);   PL(White);   S1+(Yellow);   S1-(Black);

85~260VAC

DT-DPS

PS5

Handsets

L1  L2  PL  S1+  S2+  S-

L1  L2  PL  S1+  S2+  S-

L1  L2  PL  S1+  S2+  S-

L1  L2  PL  S1+  S2+  S-

1 2

ON

1 2

ON

1 2

ON

1 2

ON

1# Panel

DIP=on,off,off

ID=00

ID=10

ID=01

ID=11

2# Panel

3# Panel

4# Panel

DBC4S

A  B  C  D

OFF

ON

Impedance 

switch

Code=0, DIP-6=off

1 2

3 4 5 6

ON

Code=3, DIP-6=on

1 2

3 4 5 6

ON

Code=2, DIP-6=off

1 2

3 4 5 6

ON

monitor 1

Code=1, DIP-6=off

1 2

3 4 5 6

ON

monitor 2

monitor 3

monitor 4

1 2

ON

ID=00

85~260AC

DPS

PS5

85~260AC

DPS

PS5

1 2

3 4 5 6

ON

1 2

3 4 5 6

Code=7, DIP-6=on

Code=5, DIP-6=on

1 2

3 4 5 6

ON

1 2

3 4 5 6

ON

Code=6, DIP-6=on

Code=4, DIP-6=on

1 2

3 4 5 6

ON

1 2

3 4 5 6

ON

Code=3, DIP-6=on

Code=1, DIP-6=on

1 2

3 4 5 6

ON

1 2

3 4 5 6

ON

Code=2, DIP-6=on

Code=0, DIP-6=on

OFF ON

OFF ON

monitor 1

monitor 3

monitor 5

monitor 7

monitor 8

monitor 6

monitor 4

monitor 2

DBC4S

A  B  C  D

DBC4S

A  B  C  D

Impedance 

switch

Impedance 

switch

DIP=on,off,off

DIP=on,off,off

1 2

ON

ID=00

-6-

Doorentryonline 

Ltd

Содержание DT595A

Страница 1: ...DT595A USER MANUAL 2 Wire Audio Entry System Read this manual carefully before using the product and keep it safe for future use D o o r e n t r y o n l i n e L t d...

Страница 2: ...be connected Please refer to DIP Switch Settings for additional door panels SPK adjust to adjust the talk volume PROG button reserved CALL button press to call the user 4P terminal to update software...

Страница 3: ...o fix the back panel and rain cover to the wall then connect the cable correctly 2 Attach the front panel to the back panel then use the screw to fix it Wiring and Connection Basic one to one connecti...

Страница 4: ...L2 PL S1 S2 S L1 L2 PL S1 S2 S 1 2 ON 1 2 ON 1 2 ON 1 2 ON 1 Panel DIP on off off ID 00 ID 10 ID 01 ID 11 2 Panel 3 Panel 4 Panel DBC4S A B C D OFF ON Impedance switch Code 0 DIP 6 off 1 2 3 4 5 6 ON...

Страница 5: ...e 4 DIP 6 on 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON Code 3 DIP 6 on Code 1 DIP 6 on 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON Code 2 DIP 6 on Code 0 DIP 6 on OFF ON OFF ON monitor 1 monitor 3 monitor 5 monitor 7 monitor 8...

Страница 6: ...LOCK Jumper position in Connect one lock 2 3 Bus PL S2 S1 S1 Note 1 The external power supply must be used according to the lock 2 The jumper must be taken off before connecting 3 Setup the Unlock Mod...

Страница 7: ...nstallation There are 6 bits in total The DIP switches are used to configure the user code for Monitors Bit 6 is an video impedance match switch which have to be set to ON if match the impedance other...

Страница 8: ...se use a small amount of pure water or diluted soap water to clean the unit The unit is weather resistant however do not spray high pressure water on the access control keypad directly Excessive moist...

Страница 9: ...y also affect the maximum distance which the system can reach Cable Usage A B C Twisted cable 2x0 75 mm2 60 60 30 80 80 40 Twisted cable 2x1 mm2 Cable Usage A B C Twisted cable 2x1 mm2 70 30 20 70 50...

Отзывы: