Generator Environment
The Generator is designed for indoor use only. It should be installed adjacent to the
application it is supplying. If this is not convenient then the unit can be sited
elsewhere, however, consideration should be made of the lengths of pipe runs as
pressure drops can result from extended runs of pipe.
Consideration should be given to the location of the generator to ensure it is
protected from extreme fluctuations in ambient temperature.
Ensure that adequate
ventilation is provided for the surrounding area, (depending on the operating
specification and model selected the generator can produce up to a maximum flow
of 2,556 L/min). Installation in a confined space or poorly ventilated space is not
recommended, however if you choose to do so ambient oxygen monitoring
equipment is recommended.
Please refer to the drawing below for the general dimensions of the unit.
Maximum Ambient Conditions: +50°C (dry bulb) 80%RH (Max) Non-Condensing
General Dimensions
The Generator must always be placed on a level surface. Failure to do so
will affect the stability of the Generator.
1738