Replacement Parts
Consumable Spares
The extraction system contains two filters. These should be
replaced when instructed to do so by the system or when
the system isn’t performing
(see section
6
for replacing the
filters).
To maintain performance it is important that the filters are
replaced with identical BOFA filters. To re-order please refer
to the Filter number printed on the filter installed in your
extraction unit.
Maintenance Protocol
Users can record changes in filter change intervals on the
table below.
Unit Serial Number:
Pre Filter
Date
Engineer
Combined Filter
Date
Engineer
Filter disposal
The combined filter is manufactured from non-toxic
materials. Filters are not re-usable, cleaning used filters is
not recommended. The method of disposal of the used
filters depends on the material deposited on them.
For your guidance
Deposit
EWC
Listing*
Comment
Non
Hazardous
15 02 03
Can be disposed of as non-
hazardous waste.
Hazardous 15 02 02M
The type of hazard needs to
be identified and the
associated risks defined.
The thresholds for these
risks can then be compared
with the amount of material
in the filters to see if they
fall into the hazardous
category, if so, the filters
will need to be disposed of
in line with the
local/national regulations.