WSO Mist Collector, WSO M
12
Inlet Hopper with Flex-Duct
This option is available for ceiling mounted units or units
on customer-supplied stands. Included components are
a 152 mm (6-in) diameter collar, 3048 mm (10-ft) flexible
duct, two 152 mm (6-in) hose clamps, and a 152 mm (6-in)
mounting collar.
1. Lift the unit approximately 1524 mm (5-ft).
2. Apply sealant around the flex-duct collar toward the
outside of the bolt pattern.
3. Align the adapter with the bottom flange of the
hopper. Fasten using bolts, washers, and hex nuts
supplied.
4. Apply sealant around the hopper’s top flange toward
the outside of the bolt pattern.
5. Align the top flange of the hopper with the bolt
pattern on the bottom of the unit and secure using
6mm bolts and washers supplied.
Note: Install a 6mm bolt into every rivnut.
6. Fasten one end of the flexible duct to the collar using
a six inch hose clamp.
7. Position the inlet collar on the machine center and
trace the inlet opening and bolt pattern. Remove inlet
collar, cut inlet hole, and drill bolt holes using a
3/16-in diameter drill bit.
8. Apply a 6mm (1/4-in) bead of sealant to the machine
center, toward the outside edge of the bolt pattern.
9. Align collar and fasten to machine center using
1/8-in customer-supplied bolts, washers, and hex
nuts.
10. Trim the flexible duct to the required length and
secure with remaining hose clamp.
Do not allow flexible duct to
create a P-Trap. See Flex-Duct
Positioning.
sealant
hopper
sealant
flex-duct collar
hose clamp
flex-duct
hose clamp
inlet collar
Inlet Hopper with Flex-Duct
Содержание WSO M