WSO Mist Collector, WSO M
10
Ceiling Mount Installation
Failure to lift the collector
correctly can result in severe
personal injury or property damage.
Use appropriate lifting equipment and adopt
all safety precautions needed for moving and
handling the equipment.
A crane or forklift is recommended for
unloading, assembly, and installation of the
collector.
Location must be clear of all obstructions,
such as utility lines or roof overhang.
Ensure weight of oil-laden unit plus weight
of required materials and equipment will be
adequately supported. Failure to comply may
result in personal injury and/or property damage.
1. Verify that the ceiling attachment points can bear the
live load.
2. Use properly sized cable or chain to attach to each
of the four eyebolts to suspend the unit from the
ceiling.
3. To prevent sway, position the chain or cable to form
a 60 degree angle to the top of the unit and a 45
degree angle along the sides.
Top View
Front View
45°
60°
customer-supplied
chain or cable
eye bolts
flat washer
existing mounting holes
use sealant
Ceiling Mount