Rigging Instructions
Failure to lift the collector
correctly can result in severe
personal injury or property damage.
Do not lift unit by the door handle.
Use appropriate lifting equipment and
adopt all safety precautions needed for
moving and handling the equipment.
A crane or forklift is recommended for
unloading, assembly, and installation of the
collector.
Location must be clear of all obstructions,
such as utility lines or roof overhang.
Suggested Tools & Equipment
Crane or Forklift
Lifting Slings/Chains
Clevis Pins
Socket Wrenches
End Wrenches
Pipe Sealant
Hand Drill / Drill Bits
Hoisting Information
Use all lifting points provided.
Use clevis connectors, not hooks, on lifting slings.
Use spreader bars to prevent damage to unit’s casing.
Check the Specification Control drawing for weight
and dimensions of the unit, subassemblies, and
components to ensure adequate crane capacity.
Allow only qualified crane operators to lift the
equipment.
Refer to applicable OSHA regulations and local
codes when using cranes, forklifts, and other
lifting equipment.
Lift unit and accessories separately, and assemble
after unit is in place.
Use drift pins to align holes in mounting flanges
during installation.
Electrical Wiring
Electrical installation must
be performed by a qualified
electrician and comply with all applicable
national and local codes.
Turn off / lock out electrical power sources
before performing service or maintenance
work.
Do not install in classified hazardous
atmospheres without an enclosure rated for
the application.
All electrical wiring and connections, including
electrical grounding, should be made in accordance
with the National Electric Code, NFPA No. 70-latest
edition.
Check local ordinances for additional requirements
that apply.
The appropriate wiring schematic and electrical
rating must be used. See unit’s rating plate for
required voltage.
If the unit is not furnished with a factory-mounted
disconnect, an electric disconnect switch having
adequate amp capacity shall be installed in
accordance with Part IX, Article 430 of the National
Electrical Code, NFPA No. 70-latest edition. Check
unit’s rating plate for voltage and amperage ratings.
Refer to the wiring diagram for the number of wires
required for main power wiring and remote wiring.