87
CODE ALARM
DESCRIPTION
E-53
Insufficient air depressure with firewood
Check the correct operation and connection of the air
pressure sensor and that the burner and ash drawer are
correctly placed in the boiler.
If this alarm occurs repeatedly, you should contact the
nearest official Technical Assistance Service.
E-54
Error in the connexion of fume sensor, Sh
The fume sensor is badly connected (reverse polarity). This
error could be also because the temperature of CCDPE card is
very low. Operation will only be permitted in the “Pellet
Only” Combustion Mode 1. If this alarm appear constantly
contact with your nearest official Technical Assistance
Service to have it replaced.
E-55
Open circuit,
Sh
fume sensor
The fume sensor is damaged or disconnected. Operation will
only be permitted in the “Pellet Only” Combustion Mode 1. If
this alarm appear constantly contact with your nearest
official Technical Assistance Service to have it replaced.