45
15.3
Manual setting of feed auger calibration
By means of this parameter the weight obtained in the feed auger
calibration procedure can be set manually. When
“Manual setting of
feed auger calibration”
parameter is displayed (
) on
"Calibration
Menu"
, press
to access and set the value desired by pressing "
+
"
o "
-
" of DHW
(19)
. The range of values selectable is OFF, 0.500 -
5.000 g.
15.4
Manual ash cleaning activation
By means of this parameter the burner ash cleaning device can be
switched on manually up to a maximum of 20 cleaning cycles.
When
“Manual ash cleaning activation”
parameter is displayed (
)
on
"Calibration Menu"
, press
to access. SET symbol blinks and
pressing
again it will be activated the cleaning system. A
countdown of 20 cycles will be displayed. When the countdown is
finished the cleaning device will stop. By pressing
the cleaning
procedure can be stopped at any time and by pressing RESET it will
return to
“Calibration Menu”
level.
15.5
Manual circulation pumps activation
By means of this parameter the circulation pumps can be switched
on manually. When
“Manual circulation pump activation”
parameter
is displayed (
) on
"Calibration Menu"
, press
to access. SET
symbol blinks and pressing
again the circulation pumps will be
activated for a period of not more than 20 minutes.
By pressing
the circulation pumps can be stopped at any time
and by pressing RESET it will return to
“Calibration Menu”
level.
16
TECHNICAL MENU
"
Technical Menu
" consists of a number of technical operating parameters that only have to be
modified by a person with sufficient technical knowledge of the meaning of each parameter. Any
inappropriate setting of a parameter of
“Technical Menu”
can cause a serious malfunctioning of the
boiler and could cause damages to people, animals or things.
To access the
“Technical Menu"
press MENU and RESET tactile buttons together for 5 seconds. Access
code ("cod") request will be displayed (see
"Entry and set the access code")
. After entering the correct
code, the first parameter of
"Technical menu"
will be displayed. Browse through the menu (
P.01
, ...,
P.27
) by pressing the symbols "
+
" or "
-
" of heating
(18)
. When the desired parameter is displayed, press
to access and set it by pressing the symbols "
+
" or "
-
" of DHW
(19)
. When the parameter has been
set, press
again, the value will be saved and the display will return to
“Technical menu”
. Press RESET
any time to go back without recording any value. The following table lists these parameters and they
are described in detail in the following sections of the manual:
Содержание Dualtherm 25
Страница 1: ...INSTALLATION AND OPERATING INSTRUCTIONS DUALTHERM ...
Страница 74: ...DualTherm 72 Boiler 2 3 4 5 7 10 9 15 16 20 21 8 17 18 19 1 6 14 11 13 12 23 28 31 29 27 25 24 22 30 26 ...
Страница 82: ...DualTherm 80 Electrical board Burner SELEDUA001 8 9 2 1 3 4 5 6 7 SELEDUA000 14 14 17 16 10 11 12 13 18 19 15 ...
Страница 90: ...DualTherm 88 NOTES ...
Страница 91: ...89 NOTES ...