INSTALLATION MANUAL
EN
WHC VERSION OPERATION (colour change):
K-PAD WHC2
has a light source with 2 selectable colour
temperatures (3000-4000K). To select, proceed as follows:
Move the hand quickly across the sensor (C) 3 times, with the
lamp on, to select the required colour temperature.
WARNING:
The Led MODULE, the power supply cable or any switch
used, are not replaceable, therefore in case of damage the
device must be entirely substituted.
WARRANTY:
The warranty on the device is valid only if powered by a
power supply provided by DOMUS Line. The warranty’s
general terms and conditions for this device are available at
www.domusline.com
A short flash of the light indicates the achievement of
maximum brightness.
The luminosity level obtained will be saved until the next
adjustment.
The output cable of
K-PAD SDM
can handle a load of max.
60W @ 24VDC included the absorption of the device
figure 4.
OPERATION K-PAD SLAVE:
The
K-PAD SLAVE
(F) is a switch-free spotlight, then it must
be turned on via a remote switch that can be placed on the
K-PAD SDM
(wired in the MASTER version) as shown in
figure 4 or it can be assigned to a separate switch connected
to the primary of the converter as shown in figure 3, or to a
remote socket where to connect the converter.
OPERATION K-PAD IR:
The switching on and off of the luminaire is simply
performed by the opening and the closing of the door that is
in front of the sensor (G).
K-PAD IR
remains in operation for
8 seconds after closing the door, and is equipped with a
safety program that shuts off after 2 hours of continuous
operation.
- The luminaire has a safety program that switches it off after
2 hours of continuous operation.
ATTENTION: K-PAD SDM
/ K-PAD IR
must be connected
directly to the electronic feeder and it must not be
connected after other electronic switches.
The sensor must not be installed near electromagnetic
sources, heat sources or exposed to direct sunlight.