EN
Installing the cooling unit
Coldmachine
18
6.1
Battery monitor
The cooling device is equipped with an electronic device to protect against revers-
ing the polarity when connecting to a battery. To protect the battery, the cooling
device switches off automatically if the voltage is insufficient (see following table).
Devices without TEC control
Devices with TEC control
7
Installing the cooling unit
!
7.1
Tools required
For
installation and assembly
, you will need the following tools:
•
Drill
•
Screwdriver
•
Open-ended spanner: 16 mm, 19 mm and 21 mm
•
Sealant and PUR foam
•
Cable, cable lugs and cable clips
•
Ester oil
Connection voltage
Switch-off voltage
Restart voltage
12 V
10.4 V
11.7 V
24 V
22.8 V
24.2 V
Connection voltage
Switch-off voltage
Restart voltage
12 V
10.7 V
13.0 V
24 V
22.0 V
26.0 V
WARNING!
The installation may only be performed by a qualified technician.