25
Separate fume extraction
1. Cut an 80mm x 40mm rectangle in the outer
wall of the caravan. The position of the cut
must be appropriate to the particular model
of refrigerator and installation conditions.
2. Connect T-piece (E) to adaptor (F) or flue
pipe (K) as required and affix with screw
(G). Ensure that heat distributor (H) is
lodged in the correct position.
3. Insert flue pipe (C) through the aperture.
4. Connect flue pipe (C) to T-piece (E). If necessary, shorten flue pipe (C) to the
required length.
5. Pack the cut with non-flammable material (e.g. Rock Wool).
6. Screw securing plate (D) into position.
7. Put cap (B) on flue pipe (C).
8. Screw on outer plate (A).
Gas installation
The rules in point 6.1 must be adhered to.
When running on gas, these appliances are intended exclusively to use
liquid gas (propane/butane) - under no circumstances should town gas or
natural gas be used (EN 27418).
A fixed, pre-set pressure regulator complying with EN 12864 must be
connected to the liquid gas cylinder.
The pressure regulator must concur with the operating pressure specified
on the data plate of the appliance. The operating pressure corresponds to
the standard pressure of the country of specification (EN 1949, EN 732).
Only one connection pressure is permissible for any one vehicle. A plate
showing the permanent, clearly legible notice must be displayed in full view
at the point where the gas cylinder is installed.
The gas connection to the appliance must be installed securely and at
zero potential using tube connectors and must be securely connected to the
vehicle (a hose connection is not permissible) (EN 1949).
Inflamable material should not be in immediate proximity to the burner.
6.7.2
Cut:
80mm high
40mm wide
6.8
min. 10 mm
max. 20 mm
Содержание Type C40/110
Страница 29: ...29...
Страница 30: ...Dometic GmbH In der Steinwiese 16 D 57074 Siegen www dometic com...