Draught-free installation

The refrigerator must be sealed in accordance with EN 1949.
Illustrated below are two typical approved methods of sealing.

Proposal 1:

Using the Installation Sealing Kit from Dometic 
(SP.No. 241 2559-00, available from Dometic)

Insert lipped seals (A) into the installation 
recesses at the bottom and at each side.

Insert deflector plate (B), fitted with a lipped seal
(A) of heavy-duty, nonflammable material, into the
installation recess (see Fig. 1).

Insert deflector plate (B) in such a way that the hot
air escapes through the air vent grating into the
open air.

Affix the discharge plate to the caravan wall, not to
the refrigerator!

In addition, discharge plate (B) with its lipped seal
(A) must seal the refrigerator off from the living
area (see Fig. 1).

Ensure that the refrigerator is installed level in the
recess.

Proposal 2:

Another option is to provide the refrigerator with a cowl (A).
The cowl (A) should ideally be affixed to the caravan wall,
not to the refrigerator. Insert sealing strips at the bottom
and sides of the cover.

Finally, push the refrigerator into the cover from the front.

Both of these installation options facilitate the remo-
val and installation of the appliance for servicing.

Comment:

Other methods of sealing may be approved. However the 

chosen method must prevent draughts entering the living space of the caravan or 
motorhome. Failure to seal correctly will allow warm air to collect around the refrigera
tor and its performance will be affected. If the cavity between the caravan wall and the 
refrigerator is sealed so that fumes cannot penetrate the living  area it is possible to 
vent the flue gas directly through the upper grille without using the aluminium flue pipe. 
For this installation method, it is recommended that the same air vent grille should be 
used at the top and at the bottom (L200), and that the T-piece of the flue pipe is turned 
45 degrees.

6.2

Fig.1

Do NOT use any easily inflammable materials (in particular silicone sealing
agent or similar) for sealing! The device manufacturer's product liability
and guarantee shall lapse if such materials are used.

Содержание Type C40/110

Страница 1: ...ns English ABSORPTION REFRIGERATOR for RECREATIONAL VEHICLES RM 7390 L Type C40 110 OPERATING INSTRUCTIONS INSTALLATION INSTRUCTIONS ABSORPTION REFRIGERATOR EN Model number Product number Serial numbe...

Страница 2: ...use by date and a minimum storage temperature of 4 C or less especially for meat poultry fish sausage pre packed foods Instructions Pack raw and cooked foods separately e g in containers aluminium foi...

Страница 3: ...inter operation 12 5 10 Interior light 13 5 11 Changing the decor panel 13 5 12 Changing the door 14 5 13 Troubleshooting 15 5 14 Maintenance 16 5 15 Product liability 16 5 16 Environmental hints 16 5...

Страница 4: ...ows and leave the room do not switch on anything electrical extinguish naked flames Never open the cooling unit it is under high pressure Work on the gas flue system and electrical components must onl...

Страница 5: ...cting Dometic Service please state the model and product numbers the serial numbers together with the MLC Code if applicable You will find this information on the data plate inside the refrigerator DE...

Страница 6: ...2 1 A energy selector switch B gas electric thermostat C manual ignition button battery powered igniter D flame indicator device galvanometer Manual Ignition with Piezo igniter Note The refrigerator...

Страница 7: ...he first time and after changing the gas cylinder the gas pipes may contain air By means of brief operation of the refrigera tor and any other gas appliances e g cookers air is removed from the gas pi...

Страница 8: ...ssary by turning rotary knob B The cooling unit s performance is influenced by ambient temperatures At ambient temperatures of 15 C up to 25 C set the knob B to the middle position The cooling unit wo...

Страница 9: ...t be packed best of all in closed containers and stored separately from each other Allow foods that have been warmed up to cool down before storing Products that could emit volatile flammable gases mu...

Страница 10: ...pe the cabinet dry with a cloth 5 Use a cloth to mop up the water from the freezer compartment 6 Switch the refrigerator back on again The layer of ice must never be removed forcibly nor may defrostin...

Страница 11: ...out of service for an extended period of time the on board shut off valve and the cylinder valve must be closed open close 1 Set energy selector switch A to position 0 OFF The appliance is now fully...

Страница 12: ...ight bulb 8V 2W for 24V DC 2 light bulbs 28V 1 5W Please contact Dometic Service centres for replacement light bulbs 2 When the ambient temperature falls below 8 C the optional winter covers should be...

Страница 13: ...7390 738 1 498 5 1 3 0 5 11 1 Open the door and loosen the hinge screw 2 Take off the door by moving it upwards 3 Unscrew the door strip 3 screws 4 Remove the decor plate and insert a new decor plate...

Страница 14: ...g 5 12 It is not always possible to change the door when the refrigerator is installed 1 T r ffnen Scharnier schraube l sen und aufbewahren 2 T r nach oben wegnehmen 5 T r aufsetzen 8 Scharnierschraub...

Страница 15: ...fuse b Start engine Failure The refrigerator does not work on 230V Possible cause Action you can take a On board fuse defective b No connection to supply voltage a Fit new fuse b Establish power conne...

Страница 16: ...FC nor HFC Ammonia a natural compound of hydrogen and nitrogen is used in the cooling unit as a coolant The non ozone hazardous cyclopentan is used as a propellant in the manufacture of the PU foam in...

Страница 17: ...apacity Usable Connection Consumption Netweight Ignition Stepped H x W x D mm incl freezer capacity of Mains Battery electricity gas Piezo cabinet depth incl door compartment freezer in 24 hrs compart...

Страница 18: ...N 1648 2 EN 60335 1 EN 60335 2 24 for Europe The gas installation must comply with national regulations Local and building control department requirements The appliance shall be installed in such a wa...

Страница 19: ...om entering the gas bur ner Compared to side ventilation this ven tilation method can allow more dirt to enter the rear area of the refrigerator which makes regular maintenance of the gas burner at le...

Страница 20: ...all not to the refrigerator Insert sealing strips at the bottom and sides of the cover Finally push the refrigerator into the cover from the front Both of these installation options facilitate the rem...

Страница 21: ...unit by means of two apertures in the caravan wall Fresh air enters at the bottom extracts the heat and exits through the upper vent grille The upper ventilation grille should be positioned as high as...

Страница 22: ...tractor insert in position only for upper ventilation system L100 and screw into position 1 Seal the mounting frame making it waterproof Item 1 does not apply for installation framess with an integrat...

Страница 23: ...erator is installed level in the recess Recess measurements Model Hight H Width W Depth T Hight HSt Depth TSt RM 7390 821 mm 525 mm 575 mm 220 mm 235 mm Securing the refrigerator In the sidewalls of t...

Страница 24: ...lodged in the correct position 2 Insert flue pipe with cover plate C through the appropriate aperture in frame I and connect to T piece E If necessary shorten flue pipe C to the required length 3 Inse...

Страница 25: ...ively to use liquid gas propane butane under no circumstances should town gas or natural gas be used EN 27418 A fixed pre set pressure regulator complying with EN 12864 must be connected to the liquid...

Страница 26: ...EN1949 A certificate of testing must be issued qualified personnel Qualified personnel are accredited experts who are able by virtue of their training and knowledge to vouch for the correct implement...

Страница 27: ...t it does not come in contact with hot components of the unit burner or with sharp edges If the connection cable is damaged it must be replaced by the Customer Service at Dometic or by respectively qu...

Страница 28: ...istor replaced by a bridge for 24V battery voltage thermo cut off current light DC reed contacts sensor switching to casing to casing heating element AC Battery connection 12V 24V A Ground heating ele...

Страница 29: ...29...

Страница 30: ...Dometic GmbH In der Steinwiese 16 D 57074 Siegen www dometic com...

Отзывы: