EN
SMP301-02/-03
Installing the power supply unit
15
SMP 301-03
Please note that flat plugs P1 – P5 are individually fused via plug-in fuses F1 – F5 in the
following manner:
➤
Press the two tabs (fig.
4
1, page 5) in the direction indicated by the arrows and
lift the cover off (fig.
4
2, page 5).
➤
Connect the positive terminal of the consumer units to the flat plugs P1 – P5
(fig.
2
6 – 10, page 3).
➤
Connect the negative terminal of the consumer units to one of the flat plugs P7
(any pin) (fig.
2
11, page 3).
➤
Connect the positive terminal of the battery to one of the flat plugs P6 (fig.
2
12,
page 3).
➤
Connect the negative terminal of the battery to one of the flat plugs P7 (any pin)
(fig.
2
11, page 3).
➤
Connect the AC connection cable to the AC plug.
➤
Ensure that the cable length between the battery and the power supply unit is not
more than 2 m.
➤
Secure all cables with strain relief clamps.
Flat plug
Fuse
Fuse assignment
Maximum permissible
current
P1
F1
10 A
15 A
P2
F2
10 A
15 A
P3
F3
5 A
15 A
P4
F4
5 A
15 A
P5
F5
10 A
15 A
SMP301-02_03-IO-7s.book Seite 15 Donnerstag, 1. Juni 2017 3:40 15