28
Refrigerator operation
Operation with batteries (internal power supply)
Indicator
Fault
Remedy
flashing
brightly l
Check burner, burner nozzles, if necessary contact
Customer Service and arrange replacement
Burner defective or coo-
ling unit defective
7
3
Automatic switching
from external to internal
power supply does not
function
(absence of the on-
board 12 V power sup-
ply for the electronics)
Switch off the refrigerator and start again.
The on-board power supply was interrupted during
the starting of the gas operation.
Note:
No automatic switching is performed during
the ignition.
Refrigerator does not
function;
gas operation not possi-
ble although the batte-
ries are inserted.
flashing
brightly
Flame not ignited
8
3
Check gas supply (gas bottle, gas valve)
Press the button after clearing the fault.
Acoustic signal at 15
second intervals
Undervoltage detection
(internal batteries)
Replace batteries
289 0457-20_EN_RMDT8xxx-Bedienung_N2_Layout 1 08.05.2015 09:30 Seite 28