background image

7

be stored in the frozen food storage compartment.
They can then be stored about three times as

long as in the fresh food storage compartment.

To prevent drying out, keep food in covered
dishes, in plastic bags or wrapped in aluminum
foil.

CAUTION

Do not store explosive substances in the re-

frigerator, such as cigarette lighter gas,

petrol, ether or the like.

Ice Making

Ice cubes can be made in the ice trays which
should be filled with water to within l/4"

(5 nun) from the top. To release the ice cubes
seize the tray with both hands and twist the
tray. Cubes not required should preferably

be replaced in the tray. Refill the tray with

water and replace the tray on the freezer

shelf.
Ice making is accelerated if the thermostat
knob is turned to setting "MAX". It is a good

idea to do this a few hours before an anti-
cipated need for ice but be sure to turn the

knob back to normal setting when the ice is

formed or the foodstuffs in the cabinet may

become frozen hard.

Defrosting

Some refrigerator models are equipped with an
automatic defrosting device incorporated with
the cooling unit. This device makes a quick
defrost of the finned evaporator section about
once a day without affecting the frozen food
storage compartment or the frozen foods contained
in. When the frozen food storage 'compartment is
covered with frost the refrigerator must be shut

down temporarily till the frost is melted. Before
the refrigerator is restarted the compartment

should be dried,

the ice trays washed and re-

filled with fresh water.

When the frost on the finned evaporator section
has melted, water will be collected in the drip

tray. The drip tray should be emptied at regular
intervals.
Some refrigerators without the automatic de-

frosting device should be defrosted regularly'
by turning off the refrigerator. Empty the re-
frigerator leaving the drip tray under the finned
evaporator and the cabinet and freezer doors

open. If desired, defrosting may be speeded up

by filling the ice tray with hot water and
placing it in the freezer.
When all frost is melted, empty the drip tray and
dry the interior of the refrigerator with a

clean cloth.

Replace the drip tray and ice tray, replace all

food stuffs and set the thermostat to "MAX" for
a few hours. Then reset the thermostat knob to
its normal position.

To Shut Down the Refrigerator

To shut down the refrigerator temporarily set
the thermostat to off and turn off the gas tap.

If the cabinet is not in operation over a period

of weeks,

it should be emptied and cleaned and

the door left ajar. The ice trays should also

be dried and kept outside the cabinet.

Cleaning

To clean the interior lining of the refrigerator
use lukewarm weak soda solution. The evaporator,

ice trays and shelves must, however, be cleaned

with warm water only. Never use strong chemicals

or abrasives to clean these parts or the pro-
tective surface will be spoiled. It is important
always to keep the refrigerator clean.

Periodic maintenance

NOTE: Before working on the refrigerator, make

sure that 110 V A. C. and optional 12 VD.C.

leads are disconnected.

Once or twice a year depending on use, it is

necessary to clean and adjust the burner assembly.

Proceed as follows:

1.

2.

3.
4.

5.

6.

7.

8.
9.

Loosen screw and remove cover plate for burner
housing.
Disconnect lighter cable from the electrode.
Loosen burner fixing screw and withdraw burner.
Clean burner tube with a brush. Blow with

compressed air.
Screw off jet and clean with alcohol. Blow

with compressed air. Never use a needle or

similar.

Clean flue baffle and flue.
Clean the cooling unit and the floor under the

refrigerator.
Reassemble.
The entire gas installation should be checked
for leaks. Test all pipe connections with
soapy water, not with an open flame.

Содержание RM360

Страница 1: ...P 7895 SW Hunziker Rd Portland OR 97223 Phone 503 620 9510 DOMETIC SALES CORP 2920 Avenue E East Alington TX 76011 P h o n e 817 277 72 1 DOMETIC SALES CORP East Oak Ridge Dr Rt 9 Box I7 A Hagerstown...

Страница 2: ...e 10 The absorption cooling unit page 10 Operation analysis for cooling unit page 10 Cooling unit replacement RM360 460 660 page 11 Cooling unit replacement RM760 page 12 The gas electric equipment pa...

Страница 3: ...r wire length in feet 3 Standard CSA Z240 6 2 C22 2 No 148 electrical requirements for recreational vehicles AWG Ventilation The installation shall be made in such a manner as to separate the combusti...

Страница 4: ...osure as shown in Fig 2 Be careful not to damage the sealing strip applied to the floor of the enclosure when the refrigerator must be blocked The heat produced at the rear of the refrigerator will ot...

Страница 5: ...21 9 16 22 3 4 32 5 16 6 21 13 16 6 23 3 4 1 1 4 RM660 40 13 16 6 23 24 11 16 6 40 21 9 16 22 3 4 40 3 16 6 21 13 16 6 23 3 4 1 1 4 RM760 52 23 24 11 16 51 3 16 21 9 16 22 3 4 51 3 8 21 13 16 6 23 3 4...

Страница 6: ...lame Blow Out If trouble is encountered with the flame blowing out under specially windy conditions try to avoid the wind blowing against the wall where vent outlets are located If the trouble persist...

Страница 7: ...d regularly by turning off the refrigerator Empty the re frigerator leaving the drip tray under the finned evaporator and the cabinet and freezer doors open If desired defrosting may be speeded up by...

Страница 8: ...edge of the panel is fitted into the bottom groove 5 Between the upper edge of the panel and the door frame there is now a gap which should be covered by the decoration strip Put the strip across the...

Страница 9: ...e middle hinge and the travel latch should change position Replacement of evaporator door on RM360 RM460 RM660 Fig 11 and 12 1 2 3 4 5 Pry the spring housings B away from the li ning so that it snaps...

Страница 10: ...iscouloured The valve is covered with a plastic can and should never be removed To remedy this fault it is recommended to remove the OPERATION ANALYSIS FOR COOLING UNIT It is obviously important that...

Страница 11: ...ual rise in tem on the evaporator inside the cabinet a smell of perature towards the boiler end ammonia may bee noticeable COOLING UNIT REPLACEMENT RM360 RM460 RM660 Remove the refrigerator from its r...

Страница 12: ...rse above procedure CAUTION 1 Be sure to apply sealing permagum 8 on the unit mounting plate Fig 16 2 Be sure to apply proper amount of Thermal Mas tic on the evaporator coil 9 3 When fitting the evap...

Страница 13: ...ame failure safety device 6 Bypass screw 7 Gas Electric thermostat 8 Pressure test gage connection 9 Capillary tube for thermostat 10 Shut off value 11 Piezo igniter 12 Firing tip 13 Flue baffle Fig 2...

Страница 14: ...ssembly of gas electric equipment 1 2 3 4 5 6 7 Press the plastic latch leftwards in Fig 22 Pull the relay out if any Snap off the fuse holder Press the spring Pull the shut off valve out Press the ga...

Страница 15: ...RATORS S Y M P T O M C A U S E P z Note It will be noted in this tabulation that T1z 48 u 8 8 2 2 several causes can be responsible for the one c rl 8 c z S effect The real cause or causes should be d...

Страница 16: ...ss of elimination investigating each possible cause starting at the top of the tabulation and proceeding to the bottom Not adequate ventilation Refrigerating unit not level Heater faulty wrong voltage...

Страница 17: ...LTS DC 12VOLTS DC N L 115 VOLTS AC THERMOS TAT 0 JUNCTION BLOCK 0 TERMINAL BLOCK GREEN GREEN YELLOW Fig 25 Wiring Diagram for Product No 926 63 01 RM760 115VOLTS AC Fig 26 Wiring Diagram for Product N...

Страница 18: ...n g Diagram f o r Product No 926 69 01 926 70 01 926 71 01 RM360 RM460 RM660 I 115 VOLTS AC m 6 BLACK j GREEN GREEN YEL LOW N_ l Lr 7 I 8 I zzz SWITCH I THERMOSTAT 0 JUNCTION BLOCK HEATER e TERMINAL B...

Страница 19: ......

Отзывы: