background image

 

United States

SALES OFFICES

DOMETIC SALES CORP.

2320 Industrial Pkwy.

Elkhart,  IN 46515
Phone 219-295-5228

DOMETIC SALES CORP.

14441 Bonelli St.
City of industry, CA 91746
Phone 818-968-9431

DOMETIC SALES CORP.

1625-A Rock Mountain Blvd.

Stone Mountain, GA 30083
Phone 404-493-6214

DOMETIC SALES CORP.

7895 SW. Hunziker Rd.

Portland, OR 97223
Phone 503-620-9510

DOMETIC SALES CORP.

2920 Avenue “E” East

Alington, TX 76011

    - P h o n e   817-277-72 1 

DOMETIC SALES CORP.

East Oak Ridge Dr.
Rt. 9, Box I7 A
Hagerstown, MD 21740
Phone 301-797-0826

Canada

Euroclean Canada Inc.

Dometic  Recreation Division

866 Langs Drive
Cambridge, Ontario

N3H  2N7 Canada

(519) 653-8880

Edition

1

Publication No.
5415-E I Service

DSC #650

etic

1

1

RM360  RM460

 

 

RM660  RM760

REFRIGERATOR

,

RM360

SERVICE MANUAL

RM460

RM660

 

RM760

Содержание RM360

Страница 1: ...P 7895 SW Hunziker Rd Portland OR 97223 Phone 503 620 9510 DOMETIC SALES CORP 2920 Avenue E East Alington TX 76011 P h o n e 817 277 72 1 DOMETIC SALES CORP East Oak Ridge Dr Rt 9 Box I7 A Hagerstown...

Страница 2: ...e 10 The absorption cooling unit page 10 Operation analysis for cooling unit page 10 Cooling unit replacement RM360 460 660 page 11 Cooling unit replacement RM760 page 12 The gas electric equipment pa...

Страница 3: ...r wire length in feet 3 Standard CSA Z240 6 2 C22 2 No 148 electrical requirements for recreational vehicles AWG Ventilation The installation shall be made in such a manner as to separate the combusti...

Страница 4: ...osure as shown in Fig 2 Be careful not to damage the sealing strip applied to the floor of the enclosure when the refrigerator must be blocked The heat produced at the rear of the refrigerator will ot...

Страница 5: ...21 9 16 22 3 4 32 5 16 6 21 13 16 6 23 3 4 1 1 4 RM660 40 13 16 6 23 24 11 16 6 40 21 9 16 22 3 4 40 3 16 6 21 13 16 6 23 3 4 1 1 4 RM760 52 23 24 11 16 51 3 16 21 9 16 22 3 4 51 3 8 21 13 16 6 23 3 4...

Страница 6: ...lame Blow Out If trouble is encountered with the flame blowing out under specially windy conditions try to avoid the wind blowing against the wall where vent outlets are located If the trouble persist...

Страница 7: ...d regularly by turning off the refrigerator Empty the re frigerator leaving the drip tray under the finned evaporator and the cabinet and freezer doors open If desired defrosting may be speeded up by...

Страница 8: ...edge of the panel is fitted into the bottom groove 5 Between the upper edge of the panel and the door frame there is now a gap which should be covered by the decoration strip Put the strip across the...

Страница 9: ...e middle hinge and the travel latch should change position Replacement of evaporator door on RM360 RM460 RM660 Fig 11 and 12 1 2 3 4 5 Pry the spring housings B away from the li ning so that it snaps...

Страница 10: ...iscouloured The valve is covered with a plastic can and should never be removed To remedy this fault it is recommended to remove the OPERATION ANALYSIS FOR COOLING UNIT It is obviously important that...

Страница 11: ...ual rise in tem on the evaporator inside the cabinet a smell of perature towards the boiler end ammonia may bee noticeable COOLING UNIT REPLACEMENT RM360 RM460 RM660 Remove the refrigerator from its r...

Страница 12: ...rse above procedure CAUTION 1 Be sure to apply sealing permagum 8 on the unit mounting plate Fig 16 2 Be sure to apply proper amount of Thermal Mas tic on the evaporator coil 9 3 When fitting the evap...

Страница 13: ...ame failure safety device 6 Bypass screw 7 Gas Electric thermostat 8 Pressure test gage connection 9 Capillary tube for thermostat 10 Shut off value 11 Piezo igniter 12 Firing tip 13 Flue baffle Fig 2...

Страница 14: ...ssembly of gas electric equipment 1 2 3 4 5 6 7 Press the plastic latch leftwards in Fig 22 Pull the relay out if any Snap off the fuse holder Press the spring Pull the shut off valve out Press the ga...

Страница 15: ...RATORS S Y M P T O M C A U S E P z Note It will be noted in this tabulation that T1z 48 u 8 8 2 2 several causes can be responsible for the one c rl 8 c z S effect The real cause or causes should be d...

Страница 16: ...ss of elimination investigating each possible cause starting at the top of the tabulation and proceeding to the bottom Not adequate ventilation Refrigerating unit not level Heater faulty wrong voltage...

Страница 17: ...LTS DC 12VOLTS DC N L 115 VOLTS AC THERMOS TAT 0 JUNCTION BLOCK 0 TERMINAL BLOCK GREEN GREEN YELLOW Fig 25 Wiring Diagram for Product No 926 63 01 RM760 115VOLTS AC Fig 26 Wiring Diagram for Product N...

Страница 18: ...n g Diagram f o r Product No 926 69 01 926 70 01 926 71 01 RM360 RM460 RM660 I 115 VOLTS AC m 6 BLACK j GREEN GREEN YEL LOW N_ l Lr 7 I 8 I zzz SWITCH I THERMOSTAT 0 JUNCTION BLOCK HEATER e TERMINAL B...

Страница 19: ......

Отзывы: