background image

1

LA-03 MODEL AWNING INSTALLATION INSTRUCTIONS

USA
SERVICE OFFICE
Dometic Corp.
509 So. Poplar St.
LaGrange, IN 46761
(260) 463-4858

CANADA
Dometic Dist.
866 Langs Dr.
Cambridge, Ontario
CANADA N3H 2N7
(519) 653-4390

For Service Center
Assistance Call:
800-544-4881

Form No. 3308443.005 12/03
(French 3308444.003)
©2003 Dometic Corporation
LaGrange, IN  46761

INSTALLATION

INSTRUCTIONS

INSTALLATION INSTRUCTIONS

FOR

810(XX)*(XX)**.000U

MODEL SERIES AWNING

MODEL

Replace (XX)* with color

Replace (XX)** with length

LA-03

LATERAL ARM

AUTOMATIC AWNING

This manual must be read and un-
derstood before installation, adjust-
ment, service, or maintenance is per-
formed. This unit must be installed
by a qualified service technician.
Modification of this product can be
extremely hazardous and could re-
sult in personal injury or property
damage.

Lire et comprendre ce manuel avant
de procéder à l'installation, à des
réglages, de l'entretien ou des
réparations. L'installation de cet
appareil doit être effectuée par un
réparateur qualifié. Toute modification
de cet appareil peut être extrêmement
dangereuse et entraîner des blessures
ou dommages matériels.

WARNING

!

AVERTISSEMENT

!

A&E Systems

Important:

 Instructions must

stay with unit.  Owner read carefully.

RECORD THIS UNIT INFORMATION FOR FUTURE
REFERENCE:

Model Number
Serial Number
Date Purchased

810(XX)*(XX)**.000U

Prod No.

958303540

Содержание LA-03

Страница 1: ...d before installation adjust ment service ormaintenanceisper formed This unit must be installed by a qualified service technician Modification of this product can be extremely hazardous and could re s...

Страница 2: ...ningisfactorypresetwitha20 slope Approvalisrequired from Dometic for alternate mounting brackets supplied by the coach manufacture and for mounting of the LA 03 awning on coaches with curved side wall...

Страница 3: ...ch directly behind the lateral arm shoulders The awning is required to be mounted a minimum of 8 feet 2 4 meters abovetheground CSA C22no 236latestedition a The awning requires 10 verticle inches of c...

Страница 4: ...r GFI Ground Fault Interrupter receptacle not supplied within reach of the 6 power cord of the awning control box See FIG 9 e Install a recessed AC outlet box FS type outside water tight notsupplied t...

Страница 5: ...e Tuck gasket down into its final position in gap between the side wall and back of awning case 7 INSTALLATIONOFCONTROLBOX Disconnect 115 volt AC Failure to follow these instructions could create a sh...

Страница 6: ...arness female receptacle plug Connect the 4 wires from the pigtail harness to the 3 conductor w ground Romex wires in the outlet box with wire nuts Black Black White White Red Red Green Green w yellow...

Страница 7: ...not intended for cold weather operation Awningwillcloseatapproximately30 F with sensor turned ON Note If the awning is open with the wind sensor ON and the wind sensor is unplugged for any reason the...

Страница 8: ...ect the Pink wire to the Positive DC source of the ignition system battery d Connect the Brown wire to the Brown pigtail wire off the control box e Connect the Brown wire to the Negative DC source of...

Страница 9: ...Note The left limit adjustment is above the lip on the front cover and hard to locate 3 Continue to adjust until the lateral arm elbow joint is 1 4 gap from its stop point See FIG 18 b Awning Over Ext...

Страница 10: ...uctor Cable to Wind Sensor Green Brown Yellow Pink Green Yellow Brown A E Systems A E Systems WIND SENSOR WIND SENSOR ON OFF RESET CIRCUIT RESET CIRCUIT LA 03 Green Yellow Stripe To Motor Red To Motor...

Отзывы: