Dometic FreshWell3000
Troubleshooting
15
Water enters the
vehicle
The condensation water drainage
openings are clogged up.
➤
Clean the drainage openings
for condensation water.
The seals are damaged.
➤
Contact an authorised
workshop.
Under-bench air
conditioner does
not switch on.
No supply voltage (230 V
w
) con-
nected.
➤
Check the power supply.
The voltage is too low (under
200 V
w
).
The voltage converter is defective.
➤
Contact an authorised work-
shop.
The defective thermal protection is
defective.
The electrical fuse of the power
supply is too low.
➤
Check the electrical fuse of the
power supply.
Under-bench air
conditioner stops
working.
The air filter is obstructed.
➤
Clean the air filter.
The voltage is too low (under
200 V
w
).
The voltage converter is defective.
➤
Contact an authorised
workshop.
The defective thermal protection is
defective.
The condenser fan is damaged.
The heat exchange coils are polluted.
The external blower is defective.
Under-bench air
conditioner does
not switch off.
One of the temperature sensors is
defective.
➤
Contact an authorised
workshop.
Problem
Cause
Remedy