EN
Dometic FreshWell3000
Installation
11
7.2
Making openings
See fig.
3
➤
Mark the position and size of the openings using the template included in
the packaging (
A
and
B
).
See fig.
4
➤
Drill out the corners (
A
).
➤
Carefully cut out the opening on the roof using a keyhole saw or a similar
tool (
B
).
Make sure no electrical power cables are damaged.
➤
Drill out a condensation water drainage opening with a diameter of
32 mm (
C
).
See fig.
5
➤
Mark the position of the angle sections (
A
) and the fastening brackets (
B
).
7.3
Installing the fastening brackets and belts
See fig.
6
➤
Fasten the four fastening brackets (
A
).
➤
Pull the belts through the fastening brackets (
B
).
➤
Install the drain pipes under the under-bench air conditioner (
C
).
➤
Fasten the under-bench air conditioner with the belts (
D
).
7.4
Installing the angle section
See fig.
7
➤
Fasten the under-bench air conditioner with the two angle sections an
three fastening screw for each as shown.
7.5
Installing the external grids
See fig.
8
➤
Fasten the external grids as shown with the screws and washers included
in the supply.