Dometic Duo-Therm 3308417.009 Скачать руководство пользователя страница 8

8

579 & 595 Installation Instructions

D.

Wiring Requirements

  1. 115 VAC Supply Line

Route a copper 12 AWG, with ground, 115 VAC

supply line from the fuse or circuit breaker box to

the roof opening.

a. This supply line must be located in the front

portion of the 14-1/4" x 14-1/4" (±1/8") open-

ing.

b. The power MUST be on a separate 20 Amp

time delay fuse or HACR circuit breaker.

c. Make sure that at least 15" of supply wire

extends into the roof opening. This ensures

and easy connection at the junction box.

d. Wiring must comply with all National, State

and Local Wiring Codes.

e. Use a steel sleeve and a grommet or equiva-

lent methods to protect the wire where it

passes into the opening.

2. Route a dedicated 12 VDC supply line (18-22

AWG) from the RV's converter or battery to

the roof opening.

a. This supply line must be located in the front

portion of the 14-1/4" x 14-1/4" (±1/8") open-

ing.

b. Make sure that at least 15" of supply wire

extends into the roof opening.

3. If system includes a gas furnace, route two 18

gauge thermostat wires from the furnace to roof

opening of the air conditioner that will control it. If

more than one furnace is to be used, route the

second set of thermostat wire to the second air

conditioner. Make sure that 15" of wire extends

into the opening.

4. Route a 4-conductor receiver cable from the

Receiver mounting position into the roof open-

ing. Make sure that at least 15" of the wire

extends into the roof opening and 6" extend at the

mounting position of the 

Receiver . See Section

E-2.

E. Receiver & Cable Installation

Note: The receiver monitors the temperature of the living

area. The following receiver location is recommended to

maintain the selected temperature setting. Any other

location must be approved by Dometic. See FIG. 9.

1. Locate the receiver in a front to rear position on

the ceiling, and to one side or the other of the

return air cover. See FIG. 8A, 8B & 8C. Mounting

the receiver from side to side is not recom-

mended, but could be mounted this way as a last

possibility.

Note: When used with the  3308120 Genesis Filtration

System, do not mount the receiver where it will interfere

with the filter removal. See FIG. 8A. When used with the

3105935 Quick Cool Return Air Grille do not install near

the discharge air duct. See FIG. 8C.

Note: To operate the air conditioner, the receiver must be

installed in a location that will allow  the remote to be in

3308120 Genesis Filtration System

Receiver May Be

Mounted Here

Receiver May Be

Mounted Here

Do Not Mount Receiver

Here, It Will Block Filter

Removal

Furn

ace

Tim

er

Unit

On

Cool

Heat

Furn

ace

Tim

er

Unit

On

Cool

Furn

ace

Tim

er

Unit

On

Furn

ace

Tim

er

Unit

On

Heat

Micro-Therm Filter System

FILTER
RESET

CLEAN
FILTER

Front

Receiver May Be

Mounted Here

Receiver May Be

Mounted Here

3105007 Return Air Grille

Receiver May Be

Mounted Here

Do Not Mount

Receiver Here

3105935 Return Air Grille

FIG. 8A

FIG. 8B

FIG. 8C

Содержание Duo-Therm 3308417.009

Страница 1: ...5 Series QUICK COOL Roof Top Air Conditioners Used With 3308417 009 Cooling Furnace 3308417 025 Cooling Furnace Heat Strip Remote Comfort Control Kit Ducted REVISION FormNo 3308489 0243 04 Replaces330...

Страница 2: ...gh heat gain accesso ries like A E outdoor patio and window awnings will reduce heat gain by removing the direct sun They also add a nice area to enjoy company during the cool of the evening D Condens...

Страница 3: ...0 KW 57915 631 13 500 11 0 54 4 2 5 5 8 325 250 0 55 0 90 16 5 20Amp 94 3 5 KW 5 0 KW 57915 731 13 500 11 3 56 0 2 5 5 8 325 250 0 55 0 90 15 0 20Amp 94 3 5 KW 5 0 KW 59516 331 15 000 11 5 50 0 2 5 5...

Страница 4: ...ation in walls and roof Geographical location where the RV will be used Personalcomfortlevelrequired 1 NormalLocation Theairconditionerisdesignedto fit over an existing roof vent opening FIG 1 Roof Ve...

Страница 5: ...1 1 2 1 3 4 1 1 2 17 17 20 7 8 3 2 2 18 1 2 3 Air Grill Perimeter 14 1 4 x 14 1 4 1 8 Opening Genesis R e a r F r o n t Rear of Unit 7 5 8 18 7 5 8 5 1 4 14 7 8 FIG 4 FIG 5 It is the responsibility o...

Страница 6: ...r coolingsurface 5 Air Distribution System Installation a Dometic Corporation recommends the basic configuration shown in FIG 7A 7B and 7C for installing this air conditioner system We have found by t...

Страница 7: ...SULATION SIDE VIEW TOWARD BACK OF RV TOP VIEW BACK OF RV LOW VOLTAGE WIRES 12VDC Furnace Load Shed Sensors FRAME CCC CONTROL CABLE S or 7 Wire Analog Cable FIG 7A Register Required FIG 7B FIG 7C Duct...

Страница 8: ...pen ing Make sure that at least 15 of the wire extendsintotheroofopeningand6 extendatthe mounting position of the Receiver See Section E 2 E Receiver Cable Installation Note Thereceivermonitorsthetemp...

Страница 9: ...RV The major living area is normally a good location 2 ReceiverCableInstallation A 4 conductor receiver cable must be routed from the roof opening to the Receiver a Choosetheshortest mostdirectroutef...

Страница 10: ...lling Air Conditioner Installing unit with 3105007 or 3105935 Return Air Cover For unit with Genesis Air Filtration System FIG 13 Divider Plate Ceiling Template Return Air Cover Return Air Grill ing S...

Страница 11: ...15 i Hold the ceiling template up to the 14 1 4 x 14 1 4 1 8 opening Be sure the large plate faces the rear of the RV Start each mounting bolt through the ceil ing template and up into the unit base p...

Страница 12: ...excess height of insulation to the air conditioner base pan Do not cover up unit rating plate Installing unit with 3308120 Genesis Air Filtration System Return Air Kit For unit with 3105007 or AC Pow...

Страница 13: ...he foam divider should be level with the ceiling 1 4 Tear off the excess at the pre cut perforations in divider FIG 26 Foam Divider Adhesive Peel Off Paper Center Divider Stick To Rear Flange On Ceili...

Страница 14: ...ion Note If using the Genesis Air Filtration System steps a and b are to be completed when installing the decorative cover a Connect the previously run 12 VDC to the red and blackwiresprotrudingfromth...

Страница 15: ...n models equipped with a solar panel see wiring instructions for the solar panel before proceeding 1 Install the slider in the return air cover and raise it to the ceiling template See FIG 32 Micro Th...

Страница 16: ...en shipped from Dometic is al ways programmed as a cool furnace model The dip switches are located in the hand held remote battery compartment See FIG 33 If the control is to be used with the electric...

Страница 17: ...Hz 1 O USE COPPER CONDUCTORS ONLY 12 VDC AUX RECEIVER TO INFRARED LO FAN HI FAN 115 VAC 60 HZ 1 O IF USED TO INFRARED AUX RECEIVER LO FAN HI FAN 12 VDC WITH OPTIONAL HEAT STRIP 579 595 115VAC 60Hz 1 O...

Страница 18: ......

Отзывы: