Dometic Duo-Therm 3308417.009 Скачать руководство пользователя страница 15

15

579 & 595 Installation Instructions

This product is equipped with a 3-wire

(grounded) system for protection against

shock hazard. Make sure that the product is

wired into a properly grounded 115 volt AC

circuit and the polarity is correct. Failure to do

so could result in death, personal injury or

damage to the equipment.

b. Connect white to white; black to black; and

green to green or bare copper wire using appro-

priate sized twist connectors.

c. Tape the twist wire connectors to the supply

wire to assure they don't vibrate off.

d. Push the wires into the box.

e. Install the cover onto the junction box.

I. Decorative Cover Installation

Installing unit with 3105007 or 3105935 Return Air

Cover. For Genesis Air Filtration System Return Air

Kit see page 15.

Note: On models equipped with a solar panel, see wiring

instructions for the solar panel before proceeding.

1. Remove the return air grill from the return air cover.

2. Place the return air cover up to the ceiling tem-

plate.

3. Install cover to template with #8 x 3/8” blunt point

Phillips head screws provided (6 required).

4. Reinstall filter return air grill into return air cover.

Align tabs with mating notches and snap into place

5. Install two hole plugs into screw holes in back of

return air cover. See FIG. 31.

6. This completes the installation of the air conditioner.

We recommend that power be supplied to the air

conditioner and check for proper operation. See

section "J. Configuration Of Remote" and refer to

Operating Manual or User's Guide for a description

of the air conditioner operation.

Installing unit with 3308120 Genesis Air Filtration

System  Return Air Kit. For 3105007 or 3105935 Re-

turn Air Kit See Page 15.

Note: On models equipped with a solar panel, see wiring

instructions for the solar panel before proceeding.

1. Install the slider in the  return air cover and raise it

to the ceiling template. See FIG. 32.

Micro-Therm Filter System

FILTER
RESET

CLEA

N

FILTE

R

Return Air

Cover

Grill

Foam

Divider

Ceiling

Template

Slider

Filter

Handle

FIG. 32

2. Route the wires from the return air cover through the

template slot leaving about 3" between, and posi-

tion wire here so they can be reached after plastic

cover is installed. See FIG. 28.

3. Place the front of the return air cover against the

ceiling and slide towards the rear. The flange on

the ceiling template will catch in the groove on the

return cover. Adjust the position (right to left) and

install the front two screws. Start and tighten the

remaining screws to hold it in place.

4. Connect together the wires from the thermostat,

control box and filter indicator.

Note: 

If solar panel is installed see instructions packaged

with solar panel option.

a. Connect the red wire from the air conditioner

and  the red wire from the filter indicator light

with the red positive 12VDC supply wire. See

FIG. 28.

b. Connect the black wire from the air conditioner

and the black wire from the filter indicator light

with the black negative 12VDC supply wire.

See FIG. 28.

Note: Number 10 cabinet screw can be used to replace the

two front screws to hold the plastic cover flush to the ceil-

ing, if required.

5. Tighten the screws holding the return air cover. Slide

the filter from the right side (looking toward the RV

front) over the wires. Make sure the wires are se-

cured above the filter and are out of its way.

6. Place grill on return air cover and snap in place.

Decal is on end over circuit board.

7. Place slide handle through slots in grill into the

slide posts. Handle will fit in either direction.

FIG. 31

Return Air

Cover

Hole

Plugs

Return

Air Grill

Содержание Duo-Therm 3308417.009

Страница 1: ...5 Series QUICK COOL Roof Top Air Conditioners Used With 3308417 009 Cooling Furnace 3308417 025 Cooling Furnace Heat Strip Remote Comfort Control Kit Ducted REVISION FormNo 3308489 0243 04 Replaces330...

Страница 2: ...gh heat gain accesso ries like A E outdoor patio and window awnings will reduce heat gain by removing the direct sun They also add a nice area to enjoy company during the cool of the evening D Condens...

Страница 3: ...0 KW 57915 631 13 500 11 0 54 4 2 5 5 8 325 250 0 55 0 90 16 5 20Amp 94 3 5 KW 5 0 KW 57915 731 13 500 11 3 56 0 2 5 5 8 325 250 0 55 0 90 15 0 20Amp 94 3 5 KW 5 0 KW 59516 331 15 000 11 5 50 0 2 5 5...

Страница 4: ...ation in walls and roof Geographical location where the RV will be used Personalcomfortlevelrequired 1 NormalLocation Theairconditionerisdesignedto fit over an existing roof vent opening FIG 1 Roof Ve...

Страница 5: ...1 1 2 1 3 4 1 1 2 17 17 20 7 8 3 2 2 18 1 2 3 Air Grill Perimeter 14 1 4 x 14 1 4 1 8 Opening Genesis R e a r F r o n t Rear of Unit 7 5 8 18 7 5 8 5 1 4 14 7 8 FIG 4 FIG 5 It is the responsibility o...

Страница 6: ...r coolingsurface 5 Air Distribution System Installation a Dometic Corporation recommends the basic configuration shown in FIG 7A 7B and 7C for installing this air conditioner system We have found by t...

Страница 7: ...SULATION SIDE VIEW TOWARD BACK OF RV TOP VIEW BACK OF RV LOW VOLTAGE WIRES 12VDC Furnace Load Shed Sensors FRAME CCC CONTROL CABLE S or 7 Wire Analog Cable FIG 7A Register Required FIG 7B FIG 7C Duct...

Страница 8: ...pen ing Make sure that at least 15 of the wire extendsintotheroofopeningand6 extendatthe mounting position of the Receiver See Section E 2 E Receiver Cable Installation Note Thereceivermonitorsthetemp...

Страница 9: ...RV The major living area is normally a good location 2 ReceiverCableInstallation A 4 conductor receiver cable must be routed from the roof opening to the Receiver a Choosetheshortest mostdirectroutef...

Страница 10: ...lling Air Conditioner Installing unit with 3105007 or 3105935 Return Air Cover For unit with Genesis Air Filtration System FIG 13 Divider Plate Ceiling Template Return Air Cover Return Air Grill ing S...

Страница 11: ...15 i Hold the ceiling template up to the 14 1 4 x 14 1 4 1 8 opening Be sure the large plate faces the rear of the RV Start each mounting bolt through the ceil ing template and up into the unit base p...

Страница 12: ...excess height of insulation to the air conditioner base pan Do not cover up unit rating plate Installing unit with 3308120 Genesis Air Filtration System Return Air Kit For unit with 3105007 or AC Pow...

Страница 13: ...he foam divider should be level with the ceiling 1 4 Tear off the excess at the pre cut perforations in divider FIG 26 Foam Divider Adhesive Peel Off Paper Center Divider Stick To Rear Flange On Ceili...

Страница 14: ...ion Note If using the Genesis Air Filtration System steps a and b are to be completed when installing the decorative cover a Connect the previously run 12 VDC to the red and blackwiresprotrudingfromth...

Страница 15: ...n models equipped with a solar panel see wiring instructions for the solar panel before proceeding 1 Install the slider in the return air cover and raise it to the ceiling template See FIG 32 Micro Th...

Страница 16: ...en shipped from Dometic is al ways programmed as a cool furnace model The dip switches are located in the hand held remote battery compartment See FIG 33 If the control is to be used with the electric...

Страница 17: ...Hz 1 O USE COPPER CONDUCTORS ONLY 12 VDC AUX RECEIVER TO INFRARED LO FAN HI FAN 115 VAC 60 HZ 1 O IF USED TO INFRARED AUX RECEIVER LO FAN HI FAN 12 VDC WITH OPTIONAL HEAT STRIP 579 595 115VAC 60Hz 1 O...

Страница 18: ......

Отзывы: