579 & 595 Installation Instructions

C. Roof Preparation

1. Opening Requirements - Before preparing the ceil-

ing opening, the type of system options must be

decided upon. If a furnace is to be connected, wires

must be run from the furnace to the Dometic A/C.

Read all of the following instructions before begin-

ning the installation.

If a roof vent opening will not be used a 14-1/4" x 14-

1/4" (±1/8") opening must be cut through the roof and

ceiling of the RV. This opening must be located

between the roof reinforcing members.

There may be electrical wiring between the

roof and the ceiling. Disconnect 115 volt AC

power cord and the positive (+) 12 volt DC  ter-

minal at the supply battery. Failure to follow

this instruction may create a shock hazard

causing death or severe personal injury.

The 14-1/4" x 14-1/4" (±1/8") opening is part of the

return air system of the Air Conditioner and must be

finished in accordance with NFPA Standard 501C

Section 2.7.2.

2. Roof Vent Removal

a. Unscrew and remove the roof vent.

b. Remove all caulking compound around open-

ing.

c. Seal all screw holes and seams where the roof

gasket is located. Use a good grade of all

weather sealant. See FIG. 5.

1-1/4"

1-1/2"

1-3/4"

1-1/2"

17"

17"

20-7/8"

3"

2"

2"

18-1/2"

3"

Air Grill Perimeter

14-1/4 x 14-1/4 (±1/8") Opening

Genesis

R

e

a

r

F

r

o

n

t

Rear

of

Unit

7-5/8"

18"

7-5/8"

5-1/4"

14-7/8"

FIG. 4

FIG. 5

It is the responsibility of the installer of this

air conditioner system to ensure structural

integrity of the RV roof. Never create a low

spot on the roof where water will collect. Wa-

ter standing around the air conditioner may

leak into the interior causing damage to the

product and the RV.

d. If the opening exceeds 14-3/8" x 14-3/8", it will

be necessary to install spacers.

e. If the opening is less than 14-1/8" x 14-1/8", it

must be enlarged.

3. New Opening- (Installation Other Than Vent Open-

ing)

a. Mark a 14-1/4" x 14-1/4" (±1/8") square on the

roof and carefully cut the opening.

b. Using the roof opening as a guide, cut the

matching hole in the ceiling.

c. The opening created must be framed to provide

adequate support and prevent air from being

drawn from the roof cavity. Lumber 3/4" or more

in thickness must be used. Remember to pro-

vide an entrance hole for power supplies, fur-

nace wiring, and 4-conductior receiver cable.

FIG. 6

Do Not Cut

Roof Structure

Or Rafters

Good-Rafters

Supported By

Cross Beams

Good Location-

Between Roof

Rafters

Frame Opening So It

Won't Collapse When

Bolting Down Unit

Leave Access For Power

Supply Wiring

15" Min. At

Front Of

Opening

3/4" Min.

Содержание Duo-Therm 3308417.009

Страница 1: ...5 Series QUICK COOL Roof Top Air Conditioners Used With 3308417 009 Cooling Furnace 3308417 025 Cooling Furnace Heat Strip Remote Comfort Control Kit Ducted REVISION FormNo 3308489 0243 04 Replaces330...

Страница 2: ...gh heat gain accesso ries like A E outdoor patio and window awnings will reduce heat gain by removing the direct sun They also add a nice area to enjoy company during the cool of the evening D Condens...

Страница 3: ...0 KW 57915 631 13 500 11 0 54 4 2 5 5 8 325 250 0 55 0 90 16 5 20Amp 94 3 5 KW 5 0 KW 57915 731 13 500 11 3 56 0 2 5 5 8 325 250 0 55 0 90 15 0 20Amp 94 3 5 KW 5 0 KW 59516 331 15 000 11 5 50 0 2 5 5...

Страница 4: ...ation in walls and roof Geographical location where the RV will be used Personalcomfortlevelrequired 1 NormalLocation Theairconditionerisdesignedto fit over an existing roof vent opening FIG 1 Roof Ve...

Страница 5: ...1 1 2 1 3 4 1 1 2 17 17 20 7 8 3 2 2 18 1 2 3 Air Grill Perimeter 14 1 4 x 14 1 4 1 8 Opening Genesis R e a r F r o n t Rear of Unit 7 5 8 18 7 5 8 5 1 4 14 7 8 FIG 4 FIG 5 It is the responsibility o...

Страница 6: ...r coolingsurface 5 Air Distribution System Installation a Dometic Corporation recommends the basic configuration shown in FIG 7A 7B and 7C for installing this air conditioner system We have found by t...

Страница 7: ...SULATION SIDE VIEW TOWARD BACK OF RV TOP VIEW BACK OF RV LOW VOLTAGE WIRES 12VDC Furnace Load Shed Sensors FRAME CCC CONTROL CABLE S or 7 Wire Analog Cable FIG 7A Register Required FIG 7B FIG 7C Duct...

Страница 8: ...pen ing Make sure that at least 15 of the wire extendsintotheroofopeningand6 extendatthe mounting position of the Receiver See Section E 2 E Receiver Cable Installation Note Thereceivermonitorsthetemp...

Страница 9: ...RV The major living area is normally a good location 2 ReceiverCableInstallation A 4 conductor receiver cable must be routed from the roof opening to the Receiver a Choosetheshortest mostdirectroutef...

Страница 10: ...lling Air Conditioner Installing unit with 3105007 or 3105935 Return Air Cover For unit with Genesis Air Filtration System FIG 13 Divider Plate Ceiling Template Return Air Cover Return Air Grill ing S...

Страница 11: ...15 i Hold the ceiling template up to the 14 1 4 x 14 1 4 1 8 opening Be sure the large plate faces the rear of the RV Start each mounting bolt through the ceil ing template and up into the unit base p...

Страница 12: ...excess height of insulation to the air conditioner base pan Do not cover up unit rating plate Installing unit with 3308120 Genesis Air Filtration System Return Air Kit For unit with 3105007 or AC Pow...

Страница 13: ...he foam divider should be level with the ceiling 1 4 Tear off the excess at the pre cut perforations in divider FIG 26 Foam Divider Adhesive Peel Off Paper Center Divider Stick To Rear Flange On Ceili...

Страница 14: ...ion Note If using the Genesis Air Filtration System steps a and b are to be completed when installing the decorative cover a Connect the previously run 12 VDC to the red and blackwiresprotrudingfromth...

Страница 15: ...n models equipped with a solar panel see wiring instructions for the solar panel before proceeding 1 Install the slider in the return air cover and raise it to the ceiling template See FIG 32 Micro Th...

Страница 16: ...en shipped from Dometic is al ways programmed as a cool furnace model The dip switches are located in the hand held remote battery compartment See FIG 33 If the control is to be used with the electric...

Страница 17: ...Hz 1 O USE COPPER CONDUCTORS ONLY 12 VDC AUX RECEIVER TO INFRARED LO FAN HI FAN 115 VAC 60 HZ 1 O IF USED TO INFRARED AUX RECEIVER LO FAN HI FAN 12 VDC WITH OPTIONAL HEAT STRIP 579 595 115VAC 60Hz 1 O...

Страница 18: ......

Отзывы: