Self-Contained Air Conditioning System
Installation
5 .2 .2 EnviroCool, MCS, and ECD Blowers
q
4
EnviroCool, MCS, and ECD System Blower Rotation
q
Screws
1. Remove the seven screws on the plate.
2. Rotate the blower to the desired position.
3. Secure the blower in place using self-tapping screws
(not provided).
5 .2 .3 Vector Compact Blowers
q
w
5
Vector Compact System Blower Rotation
q
Screws on Blower
Ring
w
Screws on Drain Pan
or Bracket
1. Remove the screws from the blower ring.
2. Remove the screws attaching the blower to the drain
pan or bracket.
3. Rotate the blower to the desired position.
4. Secure the blower in place using self-tapping screws
(not provided).
5. Plug any unused holes to prevent air loss.
5 .3 Placing the Air Filters
Air filters remove airborne particles from the cabin air
and keep the evaporator coil clean. Place one air filter,
either on the air conditioning unit or in the return air
grille, for each air conditioner unit. Refer to “General
Information” on page 4 for air filter placement.
5 .4 Placing the Grilles and Transition
Boxes
Install the supply air grille as high as possible in a location
that will provide uniform air distribution throughout the
cabin. Direct the grille louvres upward. Install the return
air grille as low and close to the air conditioning unit as
possible to ensure airflow to the evaporator.
Do not direct the supply air discharge towards the return
air grille, as this will cause the system to short cycle.
Allow for adequate clearance behind the supply air grille
for the transition box and ducting connection. Refer to
“Minimum Duct and Grille Sizes per BTU Capacity” on
page 5.
6 Installation
This section explains how to install the self-contained air
conditioning unit.