Disposal
Dometic CA1000
34
8
Disposal
➤
Place the packaging material in the appropriate recycling waste bins
wherever possible.
9
Troubleshooting
Possible malfunction
Cause
Remedies
Error message F02
:
The system does not
switch on and the display
shows an error mes-
sage.
The temperature sensor is not cor-
rectly connected.
➤
Switch off the system
➤
Switch it on again after 10 min-
utes
➤
If the fault occurs again, contact
an authorised workshop.
Error message F04
:
The condensation water
that has formed is not
being discharged, and
an error message
appears in the display.
– The pump is clogged or defec-
tive.
– The condensation water hose is
clogged.
– The float switch is defective or
jammed.
➤
Contact an authorised workshop.