WARNING
CARBON MONOXIDE POISONING
Properly seal vent assembly to prevent carbon monoxide from entering
coach.
DO NOT draw combustion air from living area.
DO NOT vent exhaust air into the living area or an enclosed porch.
WARNING
CARBON MONOXIDE POISONING
Furnace must be installed and vented according to these
instructions.
Improper
installation,
adjustment,
alteration,
service
or
maintenance can cause injury or property damage.
Improper installation location may cause furnace to produce negative
pressure, affecting combustion air or venting of other appliances.
WARNING
CARBON MONOXIDE POISONING
Properly seal door to prevent carbon monoxide from entering
coach.
Properly adjust draft cap to prevent carbon monoxide from entering
coach.
MODEL NOMENCLATURE
AF
M
D
25
1
1
1
A
Dometic
Furnace
Cabinet
Size
Voltage
Input
Btu/hr
Gas
Type
Gas
Location
Valve
Model
Rev
AF
M=medium
D=12
VDC
16K
1=LP
1=door
1=Single
A
20K
2=LD (small
vent)
25K
3=door w/
rear gas
fitting
30K
4=door
w/pigtail
35K
5=door w/
pigtail & rear
gas fitting
Contents
....................................................... 2
....................................................... 2
................................................................................... 2
INSTALLATION AND SAFETY CODESError! Bookmark not defined.
INSTALLATION CODES
...................
Error! Bookmark not defined.
.................................. 2
............................................... 3
...................................................................... 3
................................................................. 3
........................................................................... 4
....................................................... 4
....................................................................... 4
................................................. 5
........................................ 5
................................................ 6
............................................................ 6
..................................................... 6
.................................................................. 6
................................................. 7
............................................... 7
.................................................. 7
..................................................................... 8
IGNITION CONTROL DIAGNOSTIC CODES
............................ 8
............................................ 8
MODEL SPECIFICATIONS
Models
AFMD16
AFMD20
AFMD25
AFMD30
AFMD35
Type of
Gas
LP
Propane
LP
Propane
LP
Propane
LP
Propane
LP
Propane
BTU Input
16,000
20,000
25,000
30,000
34,000
BTU
Output
12,160
15,200
19,000
22,800
25,840
Duct
Static
Pressure
.20” WC
.10” WC
.10” WC
.10” WC
.10” WC
Amperage
(AMPS)
4.2*
4.2*
7.5*
7.5*
11.1*
Watts
50
50
90
90
132
Power
Supply
(Volt DC)
12
12
12
12
12
Return Air
80 in
2
80 in
2
80 in
2
80 in
2
80 in
2
Minimum
Return Air
65 in
2
65 in
2
65 in
2
65 in
2
65 in
2
(WC =
WATER
COLUMN)
*
15 AMP DECATATED CIRCUIT FOR FURNACE
DIMENSIONS
Approx.
Width
Height
Depth
Weight
Casing
16-
1/2”
7”
20”
Furnace
26lbs.
Boxed
29 lbs.
STD Door
19-
1/4”
9-
3/4”
3/4”
FLUSH
DOOR
19-
3/8”
10-
1/4”
7/32”
Vent LD
5-1/2
”
5-1/2
”
1-
1/16”
INSTALLATION AND SAFETY CODES
USA and Canada
– follow all applicable state and local codes in
the absence of local codes or regulations, refer to current
standards of:
ANSI/NFPA 1192 Recreational Vehicles Code and ANSI/RVIA LV
Low Voltage Systems in Conversion and Recreational Vehicles
CSA Z240.4, Gas-Equipped Recreational Vehicles and Mobile
Housing
National Fuel Gas Code ANSI Z223.1 and/or CAN/CGA B149
This furnace must be installed in accordance with the
manufacturer’s instructions and the manufactured Home
Construction and Safety Standard, Title 24 CFR, part 3280, or
when such standard is not applicable, the Standard for
Manufactured Home Installations. (Manufactured Home Sites,
Communities and Set-Ups), ANSI A255.1 and/or CAN/CSA-Z240
MH Series M92 Canadian Standard for Mobile Homes.”
ANSI A 255.1 and/or CAN/CSA-Z240.6.2 MH Series, Mobile
Homes
Ground National Electrical Code ANSI/NFPA 70 and/or CSA
C22.1, Part 1
Park Trailers ANSI 1195
GENERAL FURNACE INSTALLATIONS
All models can be installed in either a horizontal or vertical
mounting position horizontal installed units have the gas line
positioned on top or rear, vertical installed units must have the
vent located at the floor and gas line at right side and rear.
Always install furnace through an exterior wall.
DO NOT install furnace near tilt-out rooms, slide-outs, doors or
other projection that could obstruct furnace exhaust.
Locate furnace near midpoint of coach for single furnace
applications.
Installation must provide accessibility if any repairs are necessary
to the furnace. Failure to meet this requirement will create
additional labor costs that will be the responsibility of the installer.