A. Table - Unit Data
Model No.
Nominal
Capacity
(BTU HR)
Cooling
Electrical
Rating
Compressor
Rated Load
Amps
Compressor
Locked
Rotor
Amps
Fan Motor
Rated Load
Amps
Fan Motor
Locked
Rotor
Amps
Refrigerant
R-410A
(Oz.)
Minimum
Wire Size*
AC Circuit
Protection
***Installer
Supplied
Minimum
Generator Size**
1 Unit / 2 Units
57908.321
7,180
120 VAC
60Hz. 1PH
6.9
36.0
2.5
5.8
16.0
20 Amp
2.5 kW / 4.0 kW
57908.521
7,100
6.6
34.0
2.5
5.8
17.0
20 Amp
2.5 kW / 4.0 kW
57912.531
11,000
8.0
53.0
2.5
5.8
18.5
20 Amp
2.5 kW / 4.0 kW
57912.532
11,000
12.1
59.0
2.5
5.8
16.5
20 Amp
3.5 kW / 5.0 kW
57915.331
13,500
11.4
58.0
2.5
5.8
15.5
20 Amp
3.5 kW / 5.0 kW
57915.336
13,500
12.1
59.0
2.5
5.8
16.5
20 Amp
3.5 kW / 5.0 kW
57915.531
13,500
12.1
59.0
2.5
5.8
16.5
20 Amp
3.5 kW / 5.0 kW
57915.536
13,500
12.1
59.0
2.5
5.8
16.5
20 Amp
3.5 kW / 5.0 kW
57915.541
13,500
11.3
62.0
2.5
5.8
16.0
20 Amp
3.5 kW / 5.0 kW
57915.546
13,500
11.3
62.0
2.5
5.8
16.0
20 Amp
3.5 kW / 5.0 kW
57915.741
13,500
12.0
58.0
2.5
5.8
15.5
20 Amp
3.5 kW / 5.0 kW
57915.746
13,500
12.0
58.0
2.5
5.8
15.5
20 Amp
3.5 kW / 5.0 kW
59516.331
15,000
11.5
50.0
2.5
5.8
29.0
20 Amp
3.5 kW / 5.0 kW
59516.336
15,000
12.7
60.0
2.0
5.6
29.0
20 Amp
3.5 kW / 5.0 kW
59516.531
15,000
11.5
50.0
2.5
5.8
26.5
20 Amp
3.5 kW / 5.0 kW
59516.536
15,000
11.5
50.0
2.5
5.8
29.0
20 Amp
3.5 kW / 5.0 kW
59516.731
15,000
13.3
62.0
2.0
5.6
29.0
20 Amp
3.5 kW / 5.0 kW
59530.532
N/A
8.0
53.0
2.5
5.8
18.5
15 Amp
3.5 kW / 5.0 kW
59530.536
N/A
7.8
53.0
2.0
5.6
19.0
15 Amp
3.5 kW / 5.0 kW
520310.501
9,000
7.8
49.0
3.0
8.5
20.0
20 Amp
2.5 kW / 4.0 kW
520315.501
13,500
10.3
62.0
3.0
8.5
16.5
20 Amp
3.5 kW / 5.0 kW
520315.506
13,500
10.3
62.0
3.0
8.5
16.5
20 Amp
3.5 kW / 5.0 kW
520316.501
15,000
13.2
79.0
2.8
7.6
30.0
20 Amp
3.5 kW / 5.0 kW
520316.506
15,000
13.2
79.0
2.8
7.6
30.0
20 Amp
3.5 kW / 5.0 kW
520300.501
N/A
7.8
49.0
3.0
8.5
20.0
15 Amp
2.5 kW / 4.0 kW
600312.331
11,000
9.5
53.0
3.5
10.0
17.0
20 Amp
2.5 kW / 4.0 kW
600315.331
13,500
12.4
60.0
3.5
10.0
15.2
20 Amp
3.5 kW / 5.0 kW
600315.336
13,500
12.4
60.0
3.5
10.0
15.2
20 Amp
3.5 kW / 5.0 kW
* For wire length over 24 ft., consult the National Electrical Code for proper sizing.
** Dometic Corporation gives
GENERAL
guidelines for generator requirements. These guidelines come from experiences
people have had in actual applications. When sizing the generator, the total power usage of your RV must be considered.
Keep in mind generators lose power at high altitudes and from lack of maintenance.
*** CIRCUIT PROTECTION: Time Delay Fuse or Circuit Breaker Required.
B. Roof Requirements
● A 14-1/4″ x 14-1/4″ (±1/8″) square opening (hereinafter referred to as “roof opening”) is required for installing this
unit. This opening is part of the return air system of the unit and
MUST
be finished in accordance with NFPA 1192.
●
Roof construction with rafters/joists support frames on a minimum of 16 inch centers.
●
Minimum of 2 inches and maximum of 5-1/2 inches distance between roof to ceiling of RV.
SPECIFICATIONS