background image

11

6.  Installation Of Divider Plate

a.  Measure the ceiling to roof thickness:

 

● If distance is 2.0″ - 3-3/4″, remove perfo

-

rated tab from divider plate. See (FIG. 14).

 

● If  distance  is  3-3/4″  -  5-1/2,  remove  no 

tabs.

b.  Remove the backing paper from double-

sided tape located on ceiling template. See 

(FIG. 14).

FIG. 14

Paper Backing

2.00″ - 3.75″

c. 

 

Divider plate

 MUST 

be in-

stalled correctly. Incorrect  installation could 

cause compressor to quick-cycle, and could 

result in supply circuit overload and reduced 

product performance.

The adhesive on the double-sided 

tape is extremely sticky. Make sure 

the divider plate is properly positioned 

before pressing into place.

Place the divider plate up to bottom of the 

unit base pan firmly. The foam tape on the di

-

vider plate must seal to bottom of base pan. 

See (FIG. 15).

FIG. 15

Push Divider Plate Firmly 

Onto Base Pan

d.  With slight pressure push the divider plate 

against the double-sided tape on the ceiling 

template.

e. 

Locate the 1/8″ x 7″ x 18″ self-adhesive insu

-

lation supplied with the RAG kit. Remove the 

backing paper from the insulation and care-

fully stick onto the ceiling template divider 

plate. See (FIG. 16).

FIG. 16

Foam Tape

Place Insulation In Position

(Do Not Cover Unit Rating Plate)

Divider Plate

 

Excess width is intended to seal the di-

vider plate to the sides of the roof open-

ing. This is to help prevent cold air dis-

charge from circulating into the unit return 

air opening.

 

If the insulation is too high, stick excess 

height of the insulation to the unit base 

pan. Do not cover up unit rating plate.

f.  Place the electronic control box on the ceil-

ing template with the white 6 pin plug on the 

curb side of the RV. Do 

NOT

 attach at this 

time.

g.  Plug the 6 pin connector into matching 6 pin 

connector in the electronic control box. The 

plug is polarized and will only fit in one direc

-

tion. See (FIG. 18).

h.  Plug the supplied freeze control sensor and 

the 4 wire harness into their matching con-

nectors in the electronic control box.

i.  Insert the freeze control sensor into the 

evaporator coil fins approximately 1" above 

the bottom of the coil fins and on the left side. 

See (FIG. 17). Bend fins over sensor to se

-

cure in place.

INSTALLATION INSTRUCTIONS

Содержание 520300.501

Страница 1: ...ic Control Kit Thermostat Optional Indoor Temperature Sensor Air Conditioner LCD SZ Controls 57908 59712 57915 59516 59530 520300 520310 520315 520316 600312 600315 3316155 000 Thermostat Included Wit...

Страница 2: ...NFORMATION 14 A Frost Formation On Cooling Coil 14 B Heat Gain 14 C Condensation 14 D Air Distribution 14 WIRING DIAGRAMS 15 A Simple RV Wiring Diagram 15 B Unit Wiring Diagrams 16 DOCUMENT SYMBOLS In...

Страница 3: ...all safety information and instructions to avoid possible injury or death Read and understand these instructions be fore installing using servicing performing maintenance on this product Incorrect ins...

Страница 4: ...kW 59530 532 N A 8 0 53 0 2 5 5 8 18 5 15 Amp 3 5 kW 5 0 kW 59530 536 N A 7 8 53 0 2 0 5 6 19 0 15 Amp 3 5 kW 5 0 kW 520310 501 9 000 7 8 49 0 3 0 8 5 20 0 20 Amp 2 5 kW 4 0 kW 520315 501 13 500 10 3...

Страница 5: ...n Amount of insulation in walls and roof Geographical location where the RV will be used Personal comfort level required 1 For one unit installation The unit should be mounted slightly forward of cent...

Страница 6: ...e are no obstacles wires pipes etc inside RV s roof floor walls Shut OFF gas supply disconnect 120 Vac power from RV and disconnect positive 12 Vdc terminal from supply battery BEFORE drilling or cutt...

Страница 7: ...ame Duct Duct Frame Frame Roof Opening Roof Opening AC Power Supply Wire Low Voltage Wires 12 Vdc Furnace Indoor Temperature Sensor Cable Control Wires Roof SIDE VIEW TOWARD BACK OF RV Duct Ceiling Du...

Страница 8: ...location See E Choosing Thermostat Location on page 8 4 If system includes a gas furnace route two 18 22 AWG thermostat wires from the furnace to the roof opening of the unit that will control it If...

Страница 9: ...lors listed for the communication cable 3 conductor cable match the wire colors in the unit wire harness and the wire harness at the LCD SZ electronic control box Available wire colors may vary a Remo...

Страница 10: ...et Electrical Cord 120 Vac Power Supply Control Wires 5 Hold the ceiling template up to the roof opening Make sure the large plate faces the rear of the RV See FIG 13 a Start each mounting bolt throug...

Страница 11: ...supplied with the RAG kit Remove the backing paper from the insulation and care fully stick onto the ceiling template divider plate See FIG 16 FIG 16 Foam Tape Place Insulation In Position Do Not Cov...

Страница 12: ...hermo stat wires if applicable to the blue wires protruding from the roof opening or to the 1 4 connectors at the electronic control box using the supplied 1 4 insulated connectors The polarity of thi...

Страница 13: ...eiling tem plate 3 Install cover to template using six 6 supplied 8 x 10 mm blunt point Phillips head screws 4 Re install filter return air grille into return air cov er Align tabs with mating notches...

Страница 14: ...hades blinds and or curtains 3 Keeping windows and doors shut or minimizing usage 4 Avoid the use of heat producing appliances Operation on High Fan Cooling mode will give optimum or maximum efficienc...

Страница 15: ...15 A Simple RV Wiring Diagram OPTIONAL FIG 21 WIRING DIAGRAMS...

Страница 16: ...540 J4 J3 4 3 2 1 J5 FURNACE FURNACE 2 1 12V TSTAT 12V TSTAT PART No 3316300 000 FOR USE WITH AIR CONDITIONER PASSED DIELECTRIC FACTORY WIRING FIELD WIRING FAN LO J2 BLK 2 1 BLU 3 4 N C RED 3 1 4 2 P...