Operation 

Value Air Distribution Box (ADB), Mechanical

8 .1  Understanding the Controls

This section describes the operating controls.

q

e

e

w

t

r

30 

Operating Controls

q

 Temperature Control 

Knob 
(7 Positions)

e

 OFF

 

Position

r

 Fan-Only Speeds  

(3 Steel Gray 
Positions)

w

 Fan Control Knob

t

 

Cooling Fan Speeds  
(3 Dark Gray 
Positions)

The temperature control knob (cool only) manages 
the ON/OFF operation within a temperature range of 
approximately 65–90 °F (18–32 °C), measured at the 
ADB inlet.

The fan control knob has seven positions, including 
OFF. This knob controls the fan-only speeds (steel 
gray positions) and the cooling fan speeds (dark gray 
positions).

8 .2 Understanding the Settings

This section describes the settings for the unit.

8 .2 .1  Cooling Operation

NOTICE: 

Wait at least three minutes before restarting 

the compressor when it has been manually cycled off 
with either the selector control knob or the temperature 
set lever. Failing to do so will cause the unit to quick-
cycle and could result in compressor or supply circuit 
overload.

This section describes how to use the cooling setting to 
reduce heat on warm days or evenings.

1.  Turn the temperature control knob to one of the 

seven positions on the control panel.

2.  Select the coolness level that best satisfies your 

needs:

 

– Low Cool (shorter dash) maintains the room at the 

current comfort level. Normally, Low Cool is used 
for nighttime operation.

 

– High Cool (medium dash) provides normal or 

average cooling.

 

– Turbo Cool (longest dash) provides maximum 

cooling and dehumidification.

3.  Set the thermostat at the desired temperature level.

 

I

The compressor will cycle on and off as cooling is 
required to maintain the selected temperature level. 
The fan runs when the compressor is off to help keep 
the temperature uniform throughout the RV.

8 .2 .2  Fan-Only Operation

This section describes how to use the fan setting to 
circulate the RV air without cooling.

1.  Turn the fan control knob to one of the three steel 

gray positions on the control panel.

2.  Select the fan speed that best satisfies your needs.

 

– Low Fan (one dot/fan symbol position) provides 

low air circulation.

 

– High Fan (two dot position) provides normal or 

average cooling.

 

– Turbo Fan (three dot position) provides maximum 

air circulation.

8 .2 .3  Cooling Fan Operation

This section describes how to use the cooling fan setting 
to circulate the RV air while cooling.

1.  Turn the fan control knob to one of the three dark gray 

positions on the control panel.

2.  Select the fan speed that best satisfies your needs.

 

– Cool Low Fan (one dot/fan symbol position) 

provides low air circulation.

 

– Cool High Fan (two dot position) provides normal 

or average cooling.

 

– Cool Turbo Fan (three dot position) provides 

maximum air circulation.

Содержание 457915

Страница 1: ...uctive Harm www P65Warnings ca gov Brisk Air 457915 459516 Brisk II B57915 B59516 High Performance 540315 540316 Blizzard NXT H540315 H540316 Penguin 640312 640315 640316 Penguin II 640312C 640315C 64...

Страница 2: ...n the product properly at all times These instructions MUST stay with this product By using the product you hereby confirm that you have read all instructions guidelines and warnings carefully and tha...

Страница 3: ...maintenance of the product Installation service and maintenance must be done by a qualified service person only Do not modify this product in any way Modification can be extremely hazardous Use care w...

Страница 4: ...bs Optional Parts1 Spare Foam Divider Kit 3106756 087 1 Available as an accessory not included Accommodates a roof thickness greater than 5 5 in 140 mm and includes two spare 1 2 in 30 mm foam divider...

Страница 5: ...hJet q y t r u i w e 2 FreshJet FJX3473 FJX3573 q13 8 in 351 mm tAir Flow Clearance Area Shaded w29 6 in 753 mm e27 6 in 702 mm yCenter Line of Unit r18 0 in 457 mm Clearance uRoof Opening iFront of U...

Страница 6: ...51 mm u18 in 457 mm Clearance e27 6 in 701 mm rCenter Line of Unit iAir Flow Clearance Area Shaded tRoof Opening 3 4 4 Blizzard NXT q r i u o u t y w e 5 Blizzard NXT H540315 H540316 q13 9 in 353 mm u...

Страница 7: ...it w39 6 in 1006 mm u18 0 in 457 mm Clearance e29 9 in 760 mm rCenter Line of Unit iAir Flow Clearance Area Shaded tRoof Opening 3 4 6 Penguin q r o u i u t y w e 7 Penguin 640312 640315 q9 5 in 241 m...

Страница 8: ...mm i12 0 in 305 mm Clearance rCenter Line of Unit tRoof Opening oAir Flow Clearance Area Shaded yFront of Unit 3 5 ADB Component Dimensions This section provides the internal dimensions of the ADB com...

Страница 9: ...an opening must be cut through the roof and ceiling of the RV This opening must be located between the roof reinforcing members Consider these recommendations along with your cooling needs For a sing...

Страница 10: ...000 13 2 70 0 2 8 8 0 20 1 640312 80X 11 000 11 5 53 0 2 6 8 5 20 0 640312 83X 11 000 12 5 63 0 2 6 8 5 18 0 640312C 35X 11 000 10 5 53 0 3 5 10 0 19 0 640312C 85X 11 000 11 5 53 0 2 6 8 5 20 0 640315...

Страница 11: ...S PTCR START CAP BRN RED RED YEL BLK GRN YEL WHT WHT WHT WHT O L S 6 PIN CONN C R C HERM FAN RUN CAP RED BLU GRN YEL COMPRESSOR WHT MOTOR 11 Brisk 457915 459516 B57915 B59516 Compressor 6 Pin Conn Mot...

Страница 12: ...E Failure to follow these notices could result in damage to the rooftop component and or the RV Never create a low spot on the RV roof Maintain the structural integrity of the RV roof The roof must be...

Страница 13: ...ceed to Making a New Roof Opening on page 13 If the opening exceeds 14 4 x 14 4 in 366 x 366 mm it will be necessary to reduce the size of the opening If the opening is less than 14 1 x 14 1 in 358 x...

Страница 14: ...he 115 VAC power supply wire from the time delay fuse or circuit breaker box to the roof opening Use a listed certified non metallic sheathed single strand cable See Specifications on page 10 I IIf an...

Страница 15: ...y slightly pushing up q w 19 Return Air Opening qElectrical Cord wCeiling Thickness 3 Reach up into the return air opening of the rooftop component and pull the rooftop component electrical cord down...

Страница 16: ...1 Stacking the Foam Dividers and Placement Location qStacked Foam Dividers tFoam Divider 0 4 in 10 mm 2 wRoof Thickness yFoam Divider 1 2 in 30 mm 3 eTop Foam 0 4 in 10 mm 1 uADB Adaptor 1 rTop Foam R...

Страница 17: ...70 mm 3 5 in 90 mm 3 9 in 100 mm 4 3 in 110 mm 4 7 in 120 mm 5 5 in 140 mm 5 9 in 150 mm 6 3 in 160 mm Top Foam 0 4 in 10 mm x x x x x x x x x x Top Foam Ring 0 4 in 10 mm x x x x x x x x x x Foam Di...

Страница 18: ...n of the foam dividers is acceptable and may be required in some instances 2 To accommodate a roof thickness greater than 5 5 in 140 mm order the optional accessory kit See Tools and Materials on page...

Страница 19: ...se a four bolt pattern to secure the ADB kit This section describes how to secure the rooftop component to the roof 1 For units that fit within the 14 0 x 14 0 in 366 x 366 mm ceiling opening press th...

Страница 20: ...tion box The plug is keyed and will only fit in one direction 4 To avoid damage run the 6 pin unit electrical cord through the notch on the side of the junction box 5 Route the 115 VAC power supply wi...

Страница 21: ...inalizing the Installation ThissectiondescribeshowtocompletetheADBinstallation 1 Push the filters in completely q 28 Attaching the Control Knobs qControl Knobs 2 2 Align the keyed control knobs to the...

Страница 22: ...satisfies your needs Low Cool shorter dash maintains the room at the current comfort level Normally Low Cool is used for nighttime operation High Cool medium dash provides normal or average cooling T...

Страница 23: ...se Suggested Remedy The product does not operate The circuit breaker has activated Set or reset the circuit breaker A fuse has blown Replace the fuse The product does not operate or operates poorly an...

Страница 24: ...nent solution to high heat gain accessories like the Dometic outdoor patio or window awnings reduce the effects of direct sunlight 2 During normal operation this product is designed to remove a certai...

Страница 25: ...25 EN Value Air Distribution Box ADB Mechanical Disposal...

Страница 26: ...26 EN Disposal Value Air Distribution Box ADB Mechanical...

Страница 27: ...27 EN Value Air Distribution Box ADB Mechanical Disposal...

Страница 28: ...Mobile living made easy dometic com YOUR LOCAL DEALER dometic com dealer YOUR LOCAL SUPPORT dometic com contact YOUR LOCAL SALES OFFICE dometic com sales offices...

Отзывы: