Pre-Installation 

Value Air Distribution Box (ADB), Mechanical

q

w

e

16 

Structural Framing for a New Roof Opening 

q

 0.8 in. (20 mm) 

Minimum Width for 

the Framing Stock

e

 15.0 in. (381 mm) 

Exposed Length 

of 115 VAC Power 

Supply Wire

w

 0.3 in. (8 mm) 

Minimum Width for 

Access Hole

5.  Frame the opening so it will not collapse when 

bolting the rooftop component down. 

6.  At the front of the frame opening, leave or create 

an access hole to allow for the length of exposed 
115 VAC power supply wiring required to complete 
the installation.

7.  Using the roof opening as a guide, cut a matching 

hole in the ceiling of the RV interior.

6 .3 Routing the Wiring

 

I

The power must be on an appropriately-sized 
separate time-delay fuse or circuit breaker. See 
“Specifications” on page 10.

This section describes how to route the wiring for the 
rooftop component.

1.  Position the copper 115 VAC power supply wire, with 

ground, in the front portion of the roof opening.

2.  Route the 115 VAC power supply wire from the 

time-delay fuse or circuit breaker box to the roof 
opening. Use a listed/certified non-metallic sheathed 
single strand cable. See “Specifications” on 
page 10
.

 

I

If an AC or a vent fan were removed, the existing 
power supply wire may be used provided it is of the 
proper type, size, and location, and if it is correctly 
fused. 

3.  Make sure that at least 15.0 in. (381 mm) of the 

115 VAC power supply wire extends into the roof 
opening to ensure an easy connection at the junction 
box.

4.  Protect the 115 VAC power supply wire where it 

passes into the opening according to local and 
national standards.

6 .4  Positioning the Rooftop 
Component

NOTICE: 

Do 

not

 slide the rooftop component along a 

surface. Otherwise, damage to the gasket on the bottom 
of the rooftop component could occur and cause a leak.

1.  Remove all the contents from the carton and discard 

the carton.

2.  Place all the ADB kit contents in the RV. The ADB kit 

contains mounting hardware for the ADB that will be 
installed inside the RV.

3.  Move the rooftop component to the roof.

q

w

17 

Placing the Rooftop Model Unit 

q

 Front of the Rooftop 

Component

w

 Roof Opening

Содержание 457915

Страница 1: ...uctive Harm www P65Warnings ca gov Brisk Air 457915 459516 Brisk II B57915 B59516 High Performance 540315 540316 Blizzard NXT H540315 H540316 Penguin 640312 640315 640316 Penguin II 640312C 640315C 64...

Страница 2: ...n the product properly at all times These instructions MUST stay with this product By using the product you hereby confirm that you have read all instructions guidelines and warnings carefully and tha...

Страница 3: ...maintenance of the product Installation service and maintenance must be done by a qualified service person only Do not modify this product in any way Modification can be extremely hazardous Use care w...

Страница 4: ...bs Optional Parts1 Spare Foam Divider Kit 3106756 087 1 Available as an accessory not included Accommodates a roof thickness greater than 5 5 in 140 mm and includes two spare 1 2 in 30 mm foam divider...

Страница 5: ...hJet q y t r u i w e 2 FreshJet FJX3473 FJX3573 q13 8 in 351 mm tAir Flow Clearance Area Shaded w29 6 in 753 mm e27 6 in 702 mm yCenter Line of Unit r18 0 in 457 mm Clearance uRoof Opening iFront of U...

Страница 6: ...51 mm u18 in 457 mm Clearance e27 6 in 701 mm rCenter Line of Unit iAir Flow Clearance Area Shaded tRoof Opening 3 4 4 Blizzard NXT q r i u o u t y w e 5 Blizzard NXT H540315 H540316 q13 9 in 353 mm u...

Страница 7: ...it w39 6 in 1006 mm u18 0 in 457 mm Clearance e29 9 in 760 mm rCenter Line of Unit iAir Flow Clearance Area Shaded tRoof Opening 3 4 6 Penguin q r o u i u t y w e 7 Penguin 640312 640315 q9 5 in 241 m...

Страница 8: ...mm i12 0 in 305 mm Clearance rCenter Line of Unit tRoof Opening oAir Flow Clearance Area Shaded yFront of Unit 3 5 ADB Component Dimensions This section provides the internal dimensions of the ADB com...

Страница 9: ...an opening must be cut through the roof and ceiling of the RV This opening must be located between the roof reinforcing members Consider these recommendations along with your cooling needs For a sing...

Страница 10: ...000 13 2 70 0 2 8 8 0 20 1 640312 80X 11 000 11 5 53 0 2 6 8 5 20 0 640312 83X 11 000 12 5 63 0 2 6 8 5 18 0 640312C 35X 11 000 10 5 53 0 3 5 10 0 19 0 640312C 85X 11 000 11 5 53 0 2 6 8 5 20 0 640315...

Страница 11: ...S PTCR START CAP BRN RED RED YEL BLK GRN YEL WHT WHT WHT WHT O L S 6 PIN CONN C R C HERM FAN RUN CAP RED BLU GRN YEL COMPRESSOR WHT MOTOR 11 Brisk 457915 459516 B57915 B59516 Compressor 6 Pin Conn Mot...

Страница 12: ...E Failure to follow these notices could result in damage to the rooftop component and or the RV Never create a low spot on the RV roof Maintain the structural integrity of the RV roof The roof must be...

Страница 13: ...ceed to Making a New Roof Opening on page 13 If the opening exceeds 14 4 x 14 4 in 366 x 366 mm it will be necessary to reduce the size of the opening If the opening is less than 14 1 x 14 1 in 358 x...

Страница 14: ...he 115 VAC power supply wire from the time delay fuse or circuit breaker box to the roof opening Use a listed certified non metallic sheathed single strand cable See Specifications on page 10 I IIf an...

Страница 15: ...y slightly pushing up q w 19 Return Air Opening qElectrical Cord wCeiling Thickness 3 Reach up into the return air opening of the rooftop component and pull the rooftop component electrical cord down...

Страница 16: ...1 Stacking the Foam Dividers and Placement Location qStacked Foam Dividers tFoam Divider 0 4 in 10 mm 2 wRoof Thickness yFoam Divider 1 2 in 30 mm 3 eTop Foam 0 4 in 10 mm 1 uADB Adaptor 1 rTop Foam R...

Страница 17: ...70 mm 3 5 in 90 mm 3 9 in 100 mm 4 3 in 110 mm 4 7 in 120 mm 5 5 in 140 mm 5 9 in 150 mm 6 3 in 160 mm Top Foam 0 4 in 10 mm x x x x x x x x x x Top Foam Ring 0 4 in 10 mm x x x x x x x x x x Foam Di...

Страница 18: ...n of the foam dividers is acceptable and may be required in some instances 2 To accommodate a roof thickness greater than 5 5 in 140 mm order the optional accessory kit See Tools and Materials on page...

Страница 19: ...se a four bolt pattern to secure the ADB kit This section describes how to secure the rooftop component to the roof 1 For units that fit within the 14 0 x 14 0 in 366 x 366 mm ceiling opening press th...

Страница 20: ...tion box The plug is keyed and will only fit in one direction 4 To avoid damage run the 6 pin unit electrical cord through the notch on the side of the junction box 5 Route the 115 VAC power supply wi...

Страница 21: ...inalizing the Installation ThissectiondescribeshowtocompletetheADBinstallation 1 Push the filters in completely q 28 Attaching the Control Knobs qControl Knobs 2 2 Align the keyed control knobs to the...

Страница 22: ...satisfies your needs Low Cool shorter dash maintains the room at the current comfort level Normally Low Cool is used for nighttime operation High Cool medium dash provides normal or average cooling T...

Страница 23: ...se Suggested Remedy The product does not operate The circuit breaker has activated Set or reset the circuit breaker A fuse has blown Replace the fuse The product does not operate or operates poorly an...

Страница 24: ...nent solution to high heat gain accessories like the Dometic outdoor patio or window awnings reduce the effects of direct sunlight 2 During normal operation this product is designed to remove a certai...

Страница 25: ...25 EN Value Air Distribution Box ADB Mechanical Disposal...

Страница 26: ...26 EN Disposal Value Air Distribution Box ADB Mechanical...

Страница 27: ...27 EN Value Air Distribution Box ADB Mechanical Disposal...

Страница 28: ...Mobile living made easy dometic com YOUR LOCAL DEALER dometic com dealer YOUR LOCAL SUPPORT dometic com contact YOUR LOCAL SALES OFFICE dometic com sales offices...

Отзывы: