background image

Special Features

•  Auto Fan

See Operating Instructions for more Information on this special feature.

•  LCD Error Code

When the system determines that one of the faults listed below has occurred an error 

code will be displayed in the LCD. 

Error Codes:

E1  Loss of communication between CT Thermostat and module board. LCD will cy-

cle between E1 and previous mode setting. System will shut down.

E2  Open circuit or out of range Indoor Temperature Sensor. Heating and cooling 

operation will be locked out. Fan operation can continue to operate.

E3  Shorted Indoor Temperature Sensor. Heating and cooling  operation will be locked 

out. Fan operation can continue to operate. 

E4  Open circuit or out of range Outdoor Temperature Sensor (select models). Heat 

pump operation will be locked out. Air Conditioner, Fan, and Furnace mode of 

operation can continue to operate. 

E5  Open circuit or out of range Freeze Sensor. Air conditioner mode of operation will 

be locked out, but displays the last temperature set-point. 

In the unlikely event you experience a system failure, refer to the “SERVICE” section 

of the Operating Instructions furnished with your unit.

Fan Mode Setting

  Press the

   

/ Mode

 

button until the fan mode is active. 

Press the   or   button to cycle through the fan speed 

options Low, High, and Auto. 

Mode of Operation

A mode is an operation that can be performed by the CT

Thermostat.

  Press the

   

/ Mode

 

button to cycle through the avail-

able modes. All CT Thermostats have Cool and Furnace 

modes. Select models will have an additional mode, ei-

ther Heat Pump or Heat Strip. The active mode will dis-

play on the LCD.

 

To change the set-point, press the   button to increase 

the set point and the   button to decrease the set-point.

Inside Temperature

  To display the Inside Temperature, the CT Thermostat 

must be in the OFF Mode. Press either the   or   but-

ton to display the Inside Temperature.

 

Read these instructions carefully. These 

instructions MUST stay with this product.

CAPACITIVE TOUCH THERMOSTAT

Press To 

Increase 

Temperature 

Set-Point

Press To 

Decrease 

Temperature 

Set-Point

Press To 

Power On, 

Off, And 

Toggle 

Between 

Modes of 

Operation

USER’S GUIDE

USA

SERVICE OFFICE

Dometic Corporation

1120 North Main Street

Elkhart, IN 46514

CANADA

Dometic Corporation

46 Zatonski, Unit 3

Brantford, ON N3T 5L8

CANADA

Service Center & 

Dealer Locations

Please Visit:

www.eDometic.com

REVISION A

Form No. 3316462.000  08/16

(French 3316463.000_A) 

©2016 Dometic Corporation

LaGrange, IN 46761

Capacitive Touch Thermostat Quick Start-Up

The basic steps for operating your Air Conditioner/Heat Pump/Heat Strip (hereinafter referred to 

as “unit”) with the Capacitive Touch Thermostat (hereinafter referred to as “CT Thermostat”) are 

described in this User’s Guide. For more detailed information on modes of operation and special 

features, refer to the Operating Instructions Manual. 