Special Features
• Auto Fan
See Operating Instructions for more Information on this special feature.
• LCD Error Code
When the system determines that one of the faults listed below has occurred an error
code will be displayed in the LCD.
Error Codes:
E1 Loss of communication between CT Thermostat and module board. LCD will cy-
cle between E1 and previous mode setting. System will shut down.
E2 Open circuit or out of range Indoor Temperature Sensor. Heating and cooling
operation will be locked out. Fan operation can continue to operate.
E3 Shorted Indoor Temperature Sensor. Heating and cooling operation will be locked
out. Fan operation can continue to operate.
E4 Open circuit or out of range Outdoor Temperature Sensor (select models). Heat
pump operation will be locked out. Air Conditioner, Fan, and Furnace mode of
operation can continue to operate.
E5 Open circuit or out of range Freeze Sensor. Air conditioner mode of operation will
be locked out, but displays the last temperature set-point.
In the unlikely event you experience a system failure, refer to the “SERVICE” section
of the Operating Instructions furnished with your unit.
Fan Mode Setting
Press the
/ Mode
button until the fan mode is active.
Press the or button to cycle through the fan speed
options Low, High, and Auto.
Mode of Operation
A mode is an operation that can be performed by the CT
Thermostat.
Press the
/ Mode
button to cycle through the avail-
able modes. All CT Thermostats have Cool and Furnace
modes. Select models will have an additional mode, ei-
ther Heat Pump or Heat Strip. The active mode will dis-
play on the LCD.
To change the set-point, press the button to increase
the set point and the button to decrease the set-point.
Inside Temperature
To display the Inside Temperature, the CT Thermostat
must be in the OFF Mode. Press either the or but-
ton to display the Inside Temperature.
Read these instructions carefully. These
instructions MUST stay with this product.
CAPACITIVE TOUCH THERMOSTAT
Press To
Increase
Temperature
Set-Point
Press To
Decrease
Temperature
Set-Point
Press To
Power On,
Off, And
Toggle
Between
Modes of
Operation
USER’S GUIDE
USA
SERVICE OFFICE
Dometic Corporation
1120 North Main Street
Elkhart, IN 46514
CANADA
Dometic Corporation
46 Zatonski, Unit 3
Brantford, ON N3T 5L8
CANADA
Service Center &
Dealer Locations
Please Visit:
www.eDometic.com
REVISION A
Form No. 3316462.000 08/16
(French 3316463.000_A)
©2016 Dometic Corporation
LaGrange, IN 46761
Capacitive Touch Thermostat Quick Start-Up
The basic steps for operating your Air Conditioner/Heat Pump/Heat Strip (hereinafter referred to
as “unit”) with the Capacitive Touch Thermostat (hereinafter referred to as “CT Thermostat”) are
described in this User’s Guide. For more detailed information on modes of operation and special
features, refer to the Operating Instructions Manual.
Control Button Quick Reference
CAPACITIVE TOUCH THERMOSTAT USER’S GUIDE