10
I. Dehumidify Setting (Select Models)
To set the dehumidify set-point, the system will need to be in a mode other
than
OFF
.
Press the
DEHUMIDIFY
button. The LCD will display the “dEHm” icon, the water
droplet icon
, and the humidity set-point. The set-point can be adjusted in
5% increments from 35% to 70%. Press the
button to increase the set-point and
the
button to decrease the set-point. To disable the dehumidify operation, press
and hold the
DEHUMIDIFY
button for 3 seconds. The water droplet icon will be
turned OFF and returns to the previous settings.
MODE DESCRIPTION
A. “OFF” - Off Mode
Displays
OFF
mode in a zone.
B. “COOL” - Cool Mode
In the
COOL
mode the system will cycle the compressor ON and OFF based on
the room air temperature and the temperature set-point on the CCC 2 thermostat.
When the system calls for cooling there will be a delay of approximately 2 minutes.
During this delay, the hour glass icon will be displayed in the LCD. In auto fan, the
fan will turn ON
fi
rst followed by the compressor in approximately 15 seconds. In
this mode there are (4) fan speed selections:
LOW:
The fan operates continuously at low speed. The compressor cycles ON and
OFF.
MED:
The fan operates continuously at medium speed. The compressor cycles ON
and OFF.
PROGRAMMING & OPERATIONS
15
When program “1” or “2” is operating, the “PROG 1” or “PROG 2” icon will be dis-
played in the LCD. The zone will continue to operate in the programmed setting until
the program is manually cancelled.
To cancel the program operation, press and hold the
PROGRAM
button for 3 sec-
onds. The zone will be restored to normal operation.
SPECIAL FEATURES