You may either wire direct into the junction box for
a permanent connection or wire a molded plug into
the junction box for a plug-in connection.
a.

If a Permanent Connection: Route the power
supply line, previously installed to the roof
opening, into the junction box on the ceiling
template. Connect as described in paragraph 2.

b.

If a Plug-in Connection: Use the electric supply
line, of "D. Wiring Requirements", to power and
electrical outlet installed, according to appli-
cable law, at the end of the roof opening furthest
from the junction box.

Important:

 Do not plug the molded cord in until you

have completely installed the air conditioner and are
ready for an operational check. (Operating Instructions)

Route the molded plug set from the electric
outlet into the junctions box insuring not to
coil excess wire so it will block air flow.
Connect the plug set to the terminal block
as described in paragraph 2.

2.

Connect the power supply line to the air conditioner
at the terminal block provided in the junction box.
Connect white to white, black to black and green to
green or bare copper wire (L. N. and   respectively).

3.

Tighten the strain relief onto the power supply line to
hold firmly in place. Be careful not to pinch and short
wires.

Note: If optional electric heater is part of this installation, now
is the time to install it. Installation instructions are provided
with the electric heater kit.

4.

Carefully push all excess wire back into the junction
box and install cover onto the box with two blunt
screws provided.

5.

Plug the electrical conduit from the upper unit into
the mating switch box connector. See FIG. 13.

6.

Wrap wire tie around plug connector(s) to prevent
removal in field service.

FIG. 13

Route Power Supply
Through Romex
Connector

Plug Conduit Into
Switch Box And
Secure With Wire
Tie To  Prevent
Removal

Install

Cover

H. Air Distribution Box Installation

1.

Remove the two return air grills and filters.

2.

Slide the front end of the air box over the shafts of
the thermostat and selector switch. See FIG. 14.

FIG. 14

Slide Air Box over Controls

3.

Install four screws through legs in air box into the
pre-punched holes in the ceiling template.

4.

Install the return air grills and filters by simply push-
ing them into place.

5.

Install the two knobs provided on the ends of the
thermostat and selector switch shafts.

6.

The power supply to the air conditioner may now
be turned "ON".

7.

Your air conditioner is now installed and ready for
operation. Please read the following instructions be-
fore attempting to run the unit.

OPERATING INSTRUCTIONS

A. Controls

1. The Selector Switch has eight positions including

"OFF". This controls fan speed, heating mode, and
cooling modes. See FIG. 15.

FIG. 15

Selector Switch

3

2

1

1

2

3

FIG. 16

2. The thermostat controls the compressor ON/OFF

operation in cooling temperature range of 18.5° C to
32.5° C. See FIG. 16.

Note: The thermostat does not control the unit optional
electric heater if installed.

Thermostat

Содержание 3253.331

Страница 1: ...tion of this product can be extremely haz ardous and could result in personal injury or property damage Roof Top Air Conditioner CARAVAN MODEL B3200 TYPE 3253 331 Model B3200 SERVICE OFFICE DometicCorporation ForInformation Contact www dometic com Form No 3310147 000 Danish Dutch English Finnish French German Greek Italian Norwegian Portuguese Spanish Swedish 2005 5 05 Dometic GmbH D 57074 Siegen ...

Страница 2: ...ow for roofs more than 100mm thick C The ability of the air conditioner to maintain the desired inside temperature depends on the heat gain of the Caravan Somepreventativemeasurestakenbytheoccupantsof the Caravan can reduce the heat gain and improve the performance of the air conditioner During extremely highoutdoortemperatures theheatgainoftheCaravan may be reduced by 1 Parking the Caravan in a s...

Страница 3: ...331 NominalCompressor Capacity KW 3 2 1 5 ElectricalRating 220 240 VAC 50Hz 1 Ph Full Load Amps Compressor Motor 5 2 0 8 6 0 0 8 LockedRotorAmps Comp Motor 24 5 0 6 0 5 0 CircuitProtection 10 Amp Time Delay Fuse or Circuit Breaker Input Power KW 1 35 1 64 Minimum Wire Size Up to 8 meters use 1mm2 Copper Generator Size 1 Unit 3 5KW 2 Units 5 0KW Improper installation may damage equipment could enda...

Страница 4: ...rew holes and seams where the roof gasket is located Use a good grade of all weather sealant See FIG 6 9 1 2 39 28 3 4 20 2 1 2 22 FIG 4 24cm 102cm 74cm 51cm 6 4cm 56cm 510mm 283 mm 105 mm 105 mm 283 mm 75mm 75mm Center Line Of Opening Air Box Perimeter Keep This Area Free From Obstructions 105mm 181mm 181mm 362mmx 362mm 3 2mm Opening 543mm Center Line Of Unit 305mm 102mm 102mm Rear Of Unit 362mm ...

Страница 5: ...ct Water standing around the air conditioner may leak into the interior causing damage to the product and the Caravan CAUTION D Wiring Requirements 1 220 240 VAC Supply Line Route a copper 1mm2 with ground 220 240 VAC supply line from the time delay fuse or circuit breaker box to the roof opening a This supply line must be located in the front portion of the 362mm x 362mm 3 2mm opening b ThepowerM...

Страница 6: ...unit as necessary Roof Gasket centers over 362mm x 362mm 3 2mm 3 Removeupperductfromceilingtemplateandlocate it over blower discharge See FIG 10 Note EdgewithoutflangeinstallstowardREARofopening 4 Use two 2 sharp pointed 10 sheet metal screws to hold duct to base pan Screw holes are provided in bottom of base pan for these screws 5 Reachupintoreturnairopeningoftheairconditioner and pull the unit s...

Страница 7: ... kit 4 Carefullypushallexcesswirebackintothejunction box and install cover onto the box with two blunt screwsprovided 5 Plug the electrical conduit from the upper unit into the mating switch box connector See FIG 13 6 Wrap wire tie around plug connector s to prevent removal in field service FIG 13 Route Power Supply Through Romex Connector Plug Conduit Into Switch Box And SecureWithWire TieTo Prev...

Страница 8: ...panelsintheairbox Washthe filters with soap and warm water let dry and then reinstall Note Never run the air conditioner without return air filter in place This may plug the unit evaporator coil with dirt and may substantially affect the performance of the unit 2 Clean air box housing and control panel with a soft cloth dampened with a mild detergent Never use furniture polish or scouring powders ...

Страница 9: ...30 RoofMountAssembly Rear AirConditioner UpperDischarge Duct CeilingTemplate MountingBolts Air Box RoofOpening FIG 17 ...

Страница 10: ...H C L1 4 2 1 MOTOR 2 HEAT ACCESSORY HEAT ACCESSORY BLK BLK BLK ELEMENT LIMIT SWITCH 3 1 WHT LIMIT SWITCH BOX JUNCTION JUNCTION LINE SPLICE LINE SPLICE FIELD WIRING FIELD WIRING FACTORY WIRING TSTAT TSTAT USE COPPER CONDUCTORS ONLY USE COPPER CONDUCTORS ONLY 220 240 VAC 50 HZ 10 220 240 VAC 50 HZ 10 3105580 025 FAN CAP FAN CAP ID ID BLK YEL RED BLU WHT WHT GR YL BLK YEL RED BLU WHT WHT GR YL BRN BR...

Отзывы: