Dometic 3253.331 Скачать руководство пользователя страница 10

31

AIR CONDITIONER  WIRING DIAGRAM

AIR BOX WIRING DIAGRAM

3105595.015

PASSED

DIELECTRIC

GR/YL

FAN CAP

FAN CAP

BLU

5

6

7

GR/YL

WHT

WHT

1

2

3

4

RED

YEL

BLK

ID

BRN

BRN

RED

RUN CAP

RUN CAP

WHT

MOTOR

ID

RED

RED

R

WHT

C

S

O.L.

COMPRESSOR

COMP STARTER

COMP STARTER

PTCR

*

START

CAP

COMPRESSOR

COMPRESSOR

O.L.

R

S

C

RUN CAP

RUN CAP

7

6

5

4

3

2

1

SWITCH

ROTARY

H

C

L1

4

2

1

MOTOR

2

HEAT ACCESSORY

HEAT ACCESSORY

BLK

BLK

BLK

ELEMENT

LIMIT SWITCH

3

1

WHT

LIMIT SWITCH

BOX

JUNCTION

JUNCTION

LINE SPLICE

LINE SPLICE

FIELD WIRING

FIELD WIRING

FACTORY WIRING

TSTAT

TSTAT

USE COPPER CONDUCTORS ONLY

USE COPPER CONDUCTORS ONLY

220/240 VAC 50 HZ, 10

220/240 VAC 50 HZ, 10

3105580.025

FAN CAP

FAN CAP

ID

ID

BLK

YEL
RED
BLU
WHT
WHT

GR/YL

BLK

YEL
RED
BLU

WHT
WHT

GR/YL

BRN

BRN

WHT

RED

RED

WHT

GRY

WHT

WHT

BLK

GR/YL

GR/YL

GR/YL

BLU

4

3

ACTIVE

(L)

ACTIVE

(L)

NEUTRAL

(N)

NEUTRAL

(N)

EAR

TH

(

)

EAR

TH

(

)

GR/YL

GR/YL

PTCR

COMP STARTER

START

*

CAP

Содержание 3253.331

Страница 1: ...tion of this product can be extremely haz ardous and could result in personal injury or property damage Roof Top Air Conditioner CARAVAN MODEL B3200 TYPE 3253 331 Model B3200 SERVICE OFFICE DometicCorporation ForInformation Contact www dometic com Form No 3310147 000 Danish Dutch English Finnish French German Greek Italian Norwegian Portuguese Spanish Swedish 2005 5 05 Dometic GmbH D 57074 Siegen ...

Страница 2: ...ow for roofs more than 100mm thick C The ability of the air conditioner to maintain the desired inside temperature depends on the heat gain of the Caravan Somepreventativemeasurestakenbytheoccupantsof the Caravan can reduce the heat gain and improve the performance of the air conditioner During extremely highoutdoortemperatures theheatgainoftheCaravan may be reduced by 1 Parking the Caravan in a s...

Страница 3: ...331 NominalCompressor Capacity KW 3 2 1 5 ElectricalRating 220 240 VAC 50Hz 1 Ph Full Load Amps Compressor Motor 5 2 0 8 6 0 0 8 LockedRotorAmps Comp Motor 24 5 0 6 0 5 0 CircuitProtection 10 Amp Time Delay Fuse or Circuit Breaker Input Power KW 1 35 1 64 Minimum Wire Size Up to 8 meters use 1mm2 Copper Generator Size 1 Unit 3 5KW 2 Units 5 0KW Improper installation may damage equipment could enda...

Страница 4: ...rew holes and seams where the roof gasket is located Use a good grade of all weather sealant See FIG 6 9 1 2 39 28 3 4 20 2 1 2 22 FIG 4 24cm 102cm 74cm 51cm 6 4cm 56cm 510mm 283 mm 105 mm 105 mm 283 mm 75mm 75mm Center Line Of Opening Air Box Perimeter Keep This Area Free From Obstructions 105mm 181mm 181mm 362mmx 362mm 3 2mm Opening 543mm Center Line Of Unit 305mm 102mm 102mm Rear Of Unit 362mm ...

Страница 5: ...ct Water standing around the air conditioner may leak into the interior causing damage to the product and the Caravan CAUTION D Wiring Requirements 1 220 240 VAC Supply Line Route a copper 1mm2 with ground 220 240 VAC supply line from the time delay fuse or circuit breaker box to the roof opening a This supply line must be located in the front portion of the 362mm x 362mm 3 2mm opening b ThepowerM...

Страница 6: ...unit as necessary Roof Gasket centers over 362mm x 362mm 3 2mm 3 Removeupperductfromceilingtemplateandlocate it over blower discharge See FIG 10 Note EdgewithoutflangeinstallstowardREARofopening 4 Use two 2 sharp pointed 10 sheet metal screws to hold duct to base pan Screw holes are provided in bottom of base pan for these screws 5 Reachupintoreturnairopeningoftheairconditioner and pull the unit s...

Страница 7: ... kit 4 Carefullypushallexcesswirebackintothejunction box and install cover onto the box with two blunt screwsprovided 5 Plug the electrical conduit from the upper unit into the mating switch box connector See FIG 13 6 Wrap wire tie around plug connector s to prevent removal in field service FIG 13 Route Power Supply Through Romex Connector Plug Conduit Into Switch Box And SecureWithWire TieTo Prev...

Страница 8: ...panelsintheairbox Washthe filters with soap and warm water let dry and then reinstall Note Never run the air conditioner without return air filter in place This may plug the unit evaporator coil with dirt and may substantially affect the performance of the unit 2 Clean air box housing and control panel with a soft cloth dampened with a mild detergent Never use furniture polish or scouring powders ...

Страница 9: ...30 RoofMountAssembly Rear AirConditioner UpperDischarge Duct CeilingTemplate MountingBolts Air Box RoofOpening FIG 17 ...

Страница 10: ...H C L1 4 2 1 MOTOR 2 HEAT ACCESSORY HEAT ACCESSORY BLK BLK BLK ELEMENT LIMIT SWITCH 3 1 WHT LIMIT SWITCH BOX JUNCTION JUNCTION LINE SPLICE LINE SPLICE FIELD WIRING FIELD WIRING FACTORY WIRING TSTAT TSTAT USE COPPER CONDUCTORS ONLY USE COPPER CONDUCTORS ONLY 220 240 VAC 50 HZ 10 220 240 VAC 50 HZ 10 3105580 025 FAN CAP FAN CAP ID ID BLK YEL RED BLU WHT WHT GR YL BLK YEL RED BLU WHT WHT GR YL BRN BR...

Отзывы: