1.The system enters into the main menu by calling 95 preset or by calling
9 preset twice within 3 seconds.
2
3
4
5
6
、
、
“
”
、
、
、
【
】
【
】
【
】
【
】
【
】
【
】
Tour is the built-in function in the speed dome, it will arrange the
presets into the queue of auto-tour, and can set how long it will park
at preset. Operate auto-tour is a process of incessantly transfer each
preset. One tour can store 32 presets at most.
Click the up and down button, move the cursor to
FUNCTION SET-
TING
, click the right button enter submenu.
Click the up and down button, move the cursor to
TOUR
, click the
right button to enter menu
tour
.
Set the park time of preset: Click the up and down button, move the
cursor to
TOUR DWELL
, click the right button, there will be a sign
in the front of
TOUR DWELL
, the cursor jumps to right, click the up
and down to set park time, and the range is 000-255(s).
Set tour: move the cursor to tour dwell
00-00-00...00
, click the
right button, the first dwell is activated, click the up and down to choose
preset number, click the right button, the cursor jumps to the next dwell,
click the left button, the cursor jumps to the former dwell. After finishing
the last dwell of a line, click the left button to save. Click the left button to
exit. If set the presets of the second line, move the cursor to the second
line, Click the right button to edit continuously. When the numerical value
is "00", the following presets are invalid. A tour can set up to 32 presets.
Run tour: Click the up and down button, move the cursor to
RUN
TOUR
, click the right button to exit the menu, it stars to run tour.
7. 4
Tour
FUNCTION SETTING
PRESETS
SCAN
PATTERNS
TOUR
ZONES
TIME RUNNING
BACK
EXIT
TOUR
PO-S-TM
00 - 0- 00
00 - 0- 00
00 - 0- 00
00 - 0- 00
00 - 0- 00
00 - 0- 00
00 - 0- 00
00 - 0- 00
BACK
EXIT
PO-S-TM
00 - 0- 00
00 - 0- 00
00 - 0- 00
00 - 0- 00
00 - 0- 00
00 - 0- 00
00 - 0- 00
00 - 0- 00
PO-S-TM
00 - 0- 00
00 - 0- 00
00 - 0- 00
00 - 0- 00
00 - 0- 00
00 - 0- 00
00 - 0- 00
00 - 0- 00
PO:
S:
TM:
Preset Number, optional scope: 00-80;
Movement speed of the dome ( user can choose between 0-8 , the
dome run fastest when choose 8 , slowest when choose 1, the dome at
rest when choose 0.);
Stay time setup, optional scope: 00-60 (second).
Remark: the system will leap over the preset automatically when the
stay time of one item setting up on 0; The dome will not run the tour
of latter preset when preset or movement speed setting up on 0 .
29
Function instruction
MAIN MENU
SYSTEM SETTING
CAMERA SETTING
FUNCTION SETTING
WINDOW BLANKING
ALARMS