Page 15
Door/Window Sensor Advanced User Manual
“Configuration” Command Class Parameters
Configuration parameters are sent using a standard syntax to ensure interopera-
bility between all manufacturers’ products. All values are represented using the
hexadecimal number system.
Typical syntax is as shown below. Note that the value sent must be the exact size,
in bytes, as accepted by the setting. The “extra” spaces should be filled with zeros
(see the “value” column below.)
Example Configuration Parameter:
02 02 00 0A
Param #
Size
Value
02
(Param #2)
02
(2 Bytes)
00 0A
(10)
Table 6 -
Door/Window Sensor Configuration Parameters
Param
#
Size
Name
Available Values
Default
Value
01
This parameter sets the delay time from when the Door/Window Sensor sends the BASIC_SET command to
Association Group 2 and when the BASIC_SET(0) is sent. It accepts a value up to 65,535, in seconds.
02
BASIC_SET Off Delay
00 01 ~ FF FF
(1 ~ 65,535 in Seconds)
1E
(30 sec)
02
This parameter sets the value sent by the BASIC_SET command to Association Group 2 (for more information, see
“Assocation Groups”.)
01
BASIC_SET Level
00
(0/Turn Off Device)
01 ~ 63
(0-99)
FF
(255/Turn On Device)
FF
(255/Turn
On Device)
“Configuration” Command Class Parameters