![Dome DMWD1 Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/dome/dmwd1/dmwd1_user-manual_2517691013.webp)
Page 13
Door/Window Sensor Advanced User Manual
Compatible Command Classes
Command Class
Notes
Device Reset Locally V1 (5A)
-
Powerlevel V1 (73)
-
Battery V1(80)
-
Association Group Information V1 (59)
-
Z-Wave Plus Info V2 (5E)
Returned Value:
01 06 00 0C 06 0C 06
Z-Wave Plus Version:
01
Role Type
: 06
(Slave Sleeping Reporting)
Node Type
: 00
(Z-Wave Plus Node)
Installer Icon Type
: 0C 06
(Access Control Alarm)
User Icon Type
: 0C 06
(Access Control Alarm)
Version V2 (86)
Returned Value:
06 04 05 03 3D 41 00
Z-Wave Library Type:
06
(Routing Slave)
Protocol Version
: 04 05
Protocol Sub-Version
: 03 3D
Application Version
: 41
Application Sub-Version
: 00
Manufacturer Specific V2 (72)
Returned Value:
02 1F 03 01 01
Manufacturer ID:
02 1F
Product Type
: 03
Product ID
: 01 01
Binary Sensor (30)
The
Door/Window Sensor also sends a Binary Sensor Report when
opened or closed. See below for the SENSOR_BINARY_REPORT
parameters sent:
Sensor Type
: 0A
(Door/Window)
OPEN Value
: FF
CLOSE Value
: 00
Table 4 - Command Classes
Compatible Command Classes