Page 14
Mouser Advanced User Manual
“Configuration” Command Class Parameters
Param
#
Size
Name
Available Settings
Default
Setting
1
This parameter sets the value sent by the BASIC_SET command to Association Group 2 (for more information, see
“Assocation Groups”.)
01
BASIC_SET Level
00
(0/Turn Off Device)
01 ~ 63
(0-99)
FF
(255/Turn On Device)
FF
(255/Turn
On Device)
2
This parameter sets “firing mode” of the Mouser. Two firing modes are available: in the first (Continuous Fire,)
electricity is passed continuously for four minutes, and in the second (Burst Fire,) electricity is passed continuously
only for the first minute and it is pulsed at approximately 400 beats per minute for the remainder of the time.
01
Set Firing Mode
01
(Continuous Fire)
02
(Burst Fire)
02
(Burst Fire)
3
02
High Voltage Duration Time
00 64~01 68
(100~360 in Seconds)
64
(100
Seconds)
Table 6 -
Mouser Configuration Parameters
Configuration parameters are sent using a standard syntax to ensure interopera-
bility between all manufacturers’ products. All values are represented using the
hexadecimal number system.
Typical syntax is as shown below. Note that the value sent must be the exact size,
in bytes, as accepted by the setting. The “extra” spaces should be filled with zeros
(see the “value” column below.)
Example Configuration Parameter:
02 02 00 0A
Param #
Size
Value
02
(Param #2)
02
(2 Bytes)
00 0A
(10)
“Configuration” Command Class Parameters