STORAGE IN CASE OF PROLONGED NON-USE
- empty the condensation drainage tray
by removing the drainage plug (make
sure you have a container handy to
collect the water),
- run the device for approximately 2
hours in slow ventilation mode to dry
the internal parts,
- replace the drainage plug,
-
put them back,
- remove the hot air exhaust pipe (as
well as the permanent drainage hose if
necessary) and store it properly,
- ensure that the storage room is clean
and free of humidity. Protect the device
from dust to ensure longevity
- remove the batteries from the remote
control and store them properly.
SPECIFICATIONS
MODEL
OL-BKY29-A011A2
Power supply
Cooling Capacity
220-240 V / 50 Hz
10000BTU
Nominal maximum power
1114W / 5A (30°C, 80%)
Noise level
≤65dB(A)
Refrigerant gas / Load
R290 / 200g
Weight
2
4
kg
Maximum nominal pressure
High point: 3.2 MPa, Low point: 0.7 MPa
Minimum area of use
10m²
350*348*701mm
Dimension
Fuse
T-Type, 250 V, 3.15 A