Product Contents

The shipping box should contain the following device compotents:

Dolphin Neurostim

1. 

 OTC Treatment Device

Black Carrying Case

2. 

Wrist Strap

3. 

User Manual

4. 

Warranty Card

5. 

Please inspect contents to ensure that there is no damange to the DNS OTC 

treatment device or wrist strap before use.

Sterilization and Shelf Life

No elements of the Dolphin Neurostim OTC require sterilization. The Dolphin 

Neurostim  OTC  has  an  indefinite  shelf  life  when  stored  in  normal  room 

conditions (at a temperature of 60-90 degrees Fahrenheit at relative humidity 

levels of 15% to 90%).

User Support

For additional support, as well as additional resources (including books, 

videos, and posters) please call or email Acumed Medical Supplies Ltd. at our 

toll-free number: 1 (800) 567-7246, or: [email protected]. You may also 

visit our website at www.dolphinotc.com for more information.

Please use the following forms to document your important medical phone 

numbers for your reference when you use this device.

Home Medical Equipment Supplier: 

_________________________________

Home Healthcare Agency: 

__________________________________________

Doctor:

  ___________________________________________________________

Содержание Neurostim OTC

Страница 1: ...e 6 User Support 6 Device Features and Controls 7 Instructions for Use 8 Turning Unit On 8 Testing and Replacing the Battery 9 Adjusting the Polarity and Sensitivity 10 Holding the Unit 11 12 Locating...

Страница 2: ...e severe muscle spasms resulting in closure of your airway difficulty in breathing or adverse effects on heart rhythm or blood pressure Do not apply stimulation across your chest because the introduct...

Страница 3: ...such suppresses the sensation of pain that would otherwise serve as a protective mechanism Effectiveness is highly dependent upon patient selection by a practitioner qualified in the management of pai...

Страница 4: ...nstruating or pregnant uterus and Use caution if stimulation is applied over areas of skin that lack normal sensation Adverse Reactions You may experience skin irritation and burns beneath the stimula...

Страница 5: ...thoroughly tested for over 30 years Caution Warning Indications for Use It is strongly advised all DNS OTC users read this entire user manual before operating this device If you have any questions ple...

Страница 6: ...itions at a temperature of 60 90 degrees Fahrenheit at relative humidity levels of 15 to 90 User Support For additional support as well as additional resources including books videos and posters pleas...

Страница 7: ...larity Switch 8 Tonify Disperse Battery Compartment 9 The Dolphin Neurostim OTC is optimally powered by Duracell 9V 10 Sensitivity Adjustment Turn to adjust skin sensitivity 12 Battery Compartment 8 P...

Страница 8: ...nger tip will turn unit on The wheel will click the DNS OTC will emit an audible tone and indicator light will turn on bright green b Secondly it increases or decreases current strength during applica...

Страница 9: ...it is time to change the battery Test the battery light every few weeks To Replace the Battery The battery door can be removed by twisting a coin or similar object in the slot provided Check and repl...

Страница 10: ...2 to 3 treatments switch the polarity to positive and re treat the area Adjust Sensitivity Dial The Sensitivity Dial assists in accurate point location The DNS OTC locates areas of low impedance by m...

Страница 11: ...roperly holding unit gently place probe tip on skin with medium pressure pen to paper pressure and slowly move drag tip over general area of point waiting for indicator light to flicker off and audibl...

Страница 12: ...inside of the wrist then take the plug and insert it securely into the jack on the bottom of the DNS OTC Note The Dolphin wrist strap is a one size fits all adjustable polyester elasticised material...

Страница 13: ...is located on top of unit in front of wheel Once point has been successfully located press and hold treatment button for 20 30 seconds approximately 20 30 beeps Increasing decreasing strength of stimu...

Страница 14: ...e the extension cap onto tip of unit Use the tip of the probe as you would the tip of the unit and locate points as described in the preceding section KEY TIP The extension probe tip is encased in a r...

Страница 15: ...on Do not store the DNS OTC in a damp or moist environment Dampness may result in temporary device malfunction moisture affects the point finding ability of the device Always store the DNS OTC in a dr...

Страница 16: ...th a 1 year warranty If your device malfunctions due to defective materials and or workmanship it is fully guaranteed for one year from the date of purchase providing The enclosed warranty card is mai...

Страница 17: ...Polarity Turn Unit On Check Battery Change Battery Too Many Points Decrease 1 2 No Points Increase 4 6 Hold Ground Locate Point Treat Point Hold Down Point 20 30 Seconds Beeps Increase Current Strengt...

Страница 18: ...ere is no leakage current to the ground Search Mode During the search mode testing from 500K Ohms skin resistence produces the following output parameters Voltage 3 8 mv Pulse length 0 0909 microsecon...

Страница 19: ...ds for all polarity settings see graph Output in the stimulation mode can be varied with the intensity control Maximum amplitude intensity setting 500 Ohms resistance gives 85 microamps 10K Ohms resis...

Страница 20: ...Sq cm 0 085 Maximum Power Density Watts Sq cm 0 0747 Maximum Charge Per Pulse Coulomb 0 0000002200000 Power Battery 9 volt During Stimulation Waveform Shape Biphasic Square Wave Maximum Output Voltage...

Страница 21: ...tures and Controls 7 Instructions for Use 8 Turning on Unit 8 Testing and Replacing the Battery 9 Adjusting the Polarity and Sensitivity 10 Holding the Unit 11 12 Locating Treatment Points 13 Using th...

Отзывы: