DB 1200T
|
Dolphin Blue
|
9
Adjustment levels
The flow time is programmable on site. If necessary, the default flow time of 30 seconds
can be adjusted to any value between 5 to 2600 seconds. The Dolphin Blue Shower
Control adjustment mechanism is composed by 3 adjustment levels for changing the
flow time. An indicator light (LED) will guide you from one level to the other.
The following table shows the number of steps in each level, the duration at each step
and how to recognize in what adjusting level you are.
The following examples show how to manage the adjustment levels:
Example 1: You wish to adjust the flow time to 28 seconds.
At level 1 perform 3 steps of 1 second (you will get 3 seconds). Total: 3 seconds
Go to level 2 and perform 1 step of 5 seconds (you will get 5 seconds). Total: 8 seconds)
Go to level 3 and perform 1 step of 20 seconds (you will get 20 seconds). Total: 28
seconds.
FLOW TIME ADJUSTMENT
No. of steps
Seconds to be
increased by
touching once
Adjustment level
indicator
Level 1
100 steps
1 second
After
entering
into
adjusting
mode level
1 is
reached
Level 2
100 steps
5 second
Indicator
light blinks
twice
Level 3
100 steps
20 second
Indicator
light blinks
three times
Level 4
Indicator
light blinks
four times
Out of
adjusting
mode
Indicator
light blinks
five times
Enables the
hygiene flush
option when
available