32
999775002 - 02/2020
Repositioning
User Information
Climbing formwork 150F
a ... 1.00 - 1.20
m
NOTICE
▪
When a climbing unit is repositioned, this
opens up exposed fall-hazard locations on
the remaining sections. These exposed
locations must be made safe by putting up
an access prohibition barrier.
This access prohibition barrier must be fixed
at least 2.0
m before the drop-off edge.
▪
The personnel in charge of the repositioning
operation are responsible for positioning the
access prohibition barriers correctly.
▪
During the lifting/repositioning cycle, no site
personnel are allowed to be on the units to
be climbed, or on adjacent units for reposi-
tioning.
▪
The persons operating the climbing form-
work must use personal fall-arrest systems
to prevent falls during the lifting operation.
A
Warning sign 'No entry' 300x300mm
9775-244-01
a
a
A
A
Initial situation
Hoist the unit to be repositioned up to the
next section.
Horizontal repositioning of the prohibition barriers
A
Warning sign 'No entry' 300x300mm
B
Crane lifting tackle
9775-245-02
A
A
A
A
9775-245-01
B
A
A
A
A
9775-245-03
A
A
A
A