Motor Does Not Run
•
When the switch is on, does the LED light on the control light up?
o
No
– Continue to the next step.
o
Yes
– Continue on
▪
Check wiring for any nicks, frays, and that you have good clean
connections.
▪
Bypass the control.
•
Unplug the control leads from the red/black and orange/blue
connectors on the back of the controller.
•
Plug the two ends from the
WIRE HARNESS
together.
•
Does the pump run now?
o
If No
– Continue to the next step.
o
If Yes
– verify that the pump is turning in the correct direction.
▪
Pump head will be turning counterclockwise.
•
If it is turning counterclockwise, is it pumping?
o
If No
– go back to Pump Will Not Pump
o
If Yes - you most likely need to
replace/repair your controller