CHAPTER 7

:

PERFORMANCE CURVE

CHAPTER 8

:

ALERTS & WARNINGS

The pump displays all alerts and warnings on the 

control panel. When an alarm or warning condition 

exists, the corresponding LED will be lit on the display. 

All control panel buttons are disabled until the alarm or 

warning is acknowledged with the ENTER button, hold 

the power until display turns off.

POWER OUT FAILURE – Incoming supply voltage is 

less than 190 VAC.

PRIMING  ERROR  –  If  the  pump  is  not  defined  as 

primed within the maximum priming time it will stop and 

generate a priming alarm for 10 minutes, then attempt 

to prime again. If the pump cannot prime within 5 

attempts it will generate a permanent alarm and have 

to be manually reset.

OVERHEAT ALERT – If the drive temperature gets 

over 103 Degrees Fahrenheit the pump will slowly 

reduce speed until the temperature condition clears. 

OVER CURRENT – Indicates that the drive is 

overloaded or the motor has an electrical problem.

Once the over current condition clears, the drive will 

restart.

OVER VOLTAGE – Indicates excessive supply voltage 

or and external water source is causing the pump and 

motor to rotate thereby generating excessive voltage in 

the drives internal DC buss. You can press the STOP 

button or other mode to re-run the pump.

Alert Code Details

 Code  Error
 

Blocked/Short Circuit/Overheat

  2 

Voltage input exceeds limit

  4 

High input voltage

  8 

Low input voltage

  16 

Exceeds maximum speed

  32 

Speed is 0

  64 

Motor phase loss

  128 

Abnormal start-up

  256 

System configuration error

  512 

Stall at start-up

  1024  System operation error, contact Harris
  4096  Hardware test error, contact Harris

Содержание 90500

Страница 1: ...ce calls read this manual carefully and completely SAVE THIS INSTRUCTION MANUAL Use of aftermarket replacement parts voids warranty ATTENTION INSTALLER THIS MANUAL CONTAINS IMPORTANT INFORMATION ABOUT THE INSTALLATION OPERATION AND SAFE USE OF THIS PUMP THAT MUST BE PROVIDED TO THE END USER OF THIS PRODUCT FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS COULD RESULT IN SERIOUS INJURY INSTALLATION OPER...

Страница 2: ...2400PRM can adjust from 2400 to 2850RPM 3 BOOST Press to select and run on default speed 3250PRM can adjust from 2850 to 3450RPM 4 STOP Press to stop the pump The screen displays the present time 5 MENU Accesses the pump menu if the pump is stopped 6 MODE 1 Run programmed 16 hours clean cycle 7 MODE 2 Run programmed 24 hours clean cycle 8 Enter Save and exit the menu 9 ARROW BUTTONS UP ARROW Move ...

Страница 3: ... S2 and S4 first press ECO if not work you will need to stop the pump After 10 minutes high speed running press ECO then press arrow button to increase or decrease RPM When press MODE 1 or MODE 2 again S2 and S4 will run as just selected NOTE RPM for S2 and S4 or S1 and S3 are always the same The default for S1 and S3 is 2400RPM the adjustable range is 2400 to 2850RPM The default for S2 and S4 is ...

Страница 4: ... S4 the same adjustment method as S1 4 Follow MODE 1 s adjustment methods to adjust MODE 2 5 Could not change speed using arrow buttons when running MODE1 MODE2 Can only change the speed of MODE 1 and MODE 2 by pressing CLEAN ECO BOOST and then use arrow button UP and DOWN to change the RPM When it is done the corresponding speed in MODE 1 MODE 2 will also change You could only change according to...

Страница 5: ... 12 00 23 59 TIME SETUP AM PM Default 06 00 S1 R2 R1 S3 S2 R3 S4 R4 Default 06 00 Default 5 hours Default 3 hours Default 18 00 Default 09 00 Default 3 hours Default 21 00 Default 5 hours S1 R2 R1 S3 S2 R3 S4 R4 Default 06 00 Default 9 hours Default 3 hours Default 18 00 Default 09 00 Default 6 hours Default 24 00 Default 6 hours Control Panel Menu Structure ...

Страница 6: ... Impeller for 1 5 HP Pump 1 8b 72580071 Impeller for 3 HP Pump 1 9 65028026000 Seal Assembly 1 10 65431121080 O Ring 1 11 647258002080 Pump Cover 1 12 5225007000 Screw 3 8 16 UNC 25 4mm 4 13 65244015000 Gasket M10 8 14 648910602080 Over Cover 1 15a 65023333000 Variable Speed 1 5 HP Motor 1 15b 65023337000 Variable Speed 3 HP Motor 1 16 65225008000 Screw 3 8 16 UNC 50 8mm 4 17 648912301080 Supporti...

Страница 7: ...erate a permanent alarm and have to be manually reset OVERHEAT ALERT If the drive temperature gets over 103 Degrees Fahrenheit the pump will slowly reduce speed until the temperature condition clears OVER CURRENT Indicates that the drive is overloaded or the motor has an electrical problem Once the over current condition clears the drive will restart OVER VOLTAGE Indicates excessive supply voltage...

Страница 8: ...as a result of freezing negligence improper installation use or care shall be replaced at our option without charge within 90 days of the receipt of defective product barring unforeseen delays After 90 days to obtain warranty replacements defective components should be returned transportation paid to the place of purchase For further Doheny s service contact Doheny s cus tomer care department No r...

Отзывы: