CHAPTER 4

:

STOP AND RUN THE PUMP

Start the Pump

1.  Make sure the pump is connected with electricity.  

  When power is on, the display screen will display  

  the time.

2.  Press one of ECO/CLEAN/BOOST, the pump will  

  run. The light on the corresponding program will be  

  lit. No matter what program you select, the pump will  

  run on 2850RPM for 5 minutes to eliminate the air in  

  the pump, so the impeller will not dry grind thus to  

  cause leakage. After high-speed running, the pump  

  will run the default speed of the selected program.

Stop the Pump

1.  Press STOP of the running pump, the pump will  

  stop. The lights on the screen twinkle.

Change Pump Running Speed

1.  When the pump is running ECO/CLEAN/BOOST,  

 

press arrow buttons up or down to change the speed,  

  each press is for 50RPM. It will save automatically,  

  no need to press ENTER.

2.  Switch between ECO/CLEAN/BOOST during pump  

  operation, the pump will not run 5 minutes high  

  speed again.

3.  For MODE 1 and MODE 2, to change speed of S1  

  and  S3,  first  press  CLEAN,  if  not  work,  you  will  

  need to stop the pump first. After 5 minutes high  

  speed running, press CLEAN, then press arrow  

  button to increase or decrease RPM. When press  

  MODE 1 or MODE 2 again to run the pump, S1 and  

  S3 will run as just selected.

  To adjust S2 and S4, first press ECO, if not work,  

  you will need to stop the pump. After 10 minutes  

  high speed running, press ECO, then press arrow  

  button to increase or decrease RPM . When press  

  MODE 1 or MODE 2 again, S2 and S4 will run as  

  just selected.

NOTE

: RPM for S2 and S4 or S1 and S3 are always 

the same. The default for S1 and S3 is 2400RPM, the 

adjustable range is 2400 to 2850RPM. The default for 

S2 and S4 is 1500RPM.The adjustable range is 1000 

to 2400PRM.

Pump Run Under Pre-Programmed Conditions

Pump has three quick start button ECO / CLEAN / 

BOOST, as below image. The default speed is 1500, 

2400, 3250RPM respectively.

1.  Be sure the pump is power on.

2.  Press one of ECO/CLEAN/BOOST, the LED light  

  on screen will be lit.

3.  The screen will display STUP for 1 second, and run  

  2850PRM for 5 minutes. After 10 minutes, the  

  pump will run on the selected speed.

CHAPTER 5

:

PUMP RUN UNDER MODE1 / MODE2

Mode 1 / Mode 2 Introduction

Running hours and RPMS are all adjustable.

ECO

Indicator Light

1000-2400RPM

Default: 1500

2400-2850RPM

Default: 2400

2850-3450RPM

Default: 3250

CLEAN

BOOST

MODE 1 - 16 Hour Running Cycle

 Stage  Start  Running  Default 

Quick

   Time  Hour  Speed  Start

 S1  6:00

 am

 3 

adjustable

  2400 RPM  CLEAN

 S2  9:00

 am

 5

 adjustable

  1500 RPM 

ECO

 S3  6:00

 pm

 3 

adjustable

  2400 RPM  CLEAN

 S4  9:00

 pm

 5

 adjustable

  1500 RPM 

ECO

  

MODE 2 - 24 Hour Running Cycle

 Stage  Start  Running  Default 

Quick

   Time  Hour  Speed  Start

 S1 12:00

 pm

 6 

adjustable

  1500 RPM 

ECO

 S2  6:00

 am

 3

 adjustable

  2400 RPM  CLEAN

 S3  9:00

 am

 9 

adjustable

  1500 RPM 

ECO

 S4  6:00

 pm

 6

 adjustable

  2400 RPM  CLEAN

Содержание 90500

Страница 1: ...ce calls read this manual carefully and completely SAVE THIS INSTRUCTION MANUAL Use of aftermarket replacement parts voids warranty ATTENTION INSTALLER THIS MANUAL CONTAINS IMPORTANT INFORMATION ABOUT THE INSTALLATION OPERATION AND SAFE USE OF THIS PUMP THAT MUST BE PROVIDED TO THE END USER OF THIS PRODUCT FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS COULD RESULT IN SERIOUS INJURY INSTALLATION OPER...

Страница 2: ...2400PRM can adjust from 2400 to 2850RPM 3 BOOST Press to select and run on default speed 3250PRM can adjust from 2850 to 3450RPM 4 STOP Press to stop the pump The screen displays the present time 5 MENU Accesses the pump menu if the pump is stopped 6 MODE 1 Run programmed 16 hours clean cycle 7 MODE 2 Run programmed 24 hours clean cycle 8 Enter Save and exit the menu 9 ARROW BUTTONS UP ARROW Move ...

Страница 3: ... S2 and S4 first press ECO if not work you will need to stop the pump After 10 minutes high speed running press ECO then press arrow button to increase or decrease RPM When press MODE 1 or MODE 2 again S2 and S4 will run as just selected NOTE RPM for S2 and S4 or S1 and S3 are always the same The default for S1 and S3 is 2400RPM the adjustable range is 2400 to 2850RPM The default for S2 and S4 is ...

Страница 4: ... S4 the same adjustment method as S1 4 Follow MODE 1 s adjustment methods to adjust MODE 2 5 Could not change speed using arrow buttons when running MODE1 MODE2 Can only change the speed of MODE 1 and MODE 2 by pressing CLEAN ECO BOOST and then use arrow button UP and DOWN to change the RPM When it is done the corresponding speed in MODE 1 MODE 2 will also change You could only change according to...

Страница 5: ... 12 00 23 59 TIME SETUP AM PM Default 06 00 S1 R2 R1 S3 S2 R3 S4 R4 Default 06 00 Default 5 hours Default 3 hours Default 18 00 Default 09 00 Default 3 hours Default 21 00 Default 5 hours S1 R2 R1 S3 S2 R3 S4 R4 Default 06 00 Default 9 hours Default 3 hours Default 18 00 Default 09 00 Default 6 hours Default 24 00 Default 6 hours Control Panel Menu Structure ...

Страница 6: ... Impeller for 1 5 HP Pump 1 8b 72580071 Impeller for 3 HP Pump 1 9 65028026000 Seal Assembly 1 10 65431121080 O Ring 1 11 647258002080 Pump Cover 1 12 5225007000 Screw 3 8 16 UNC 25 4mm 4 13 65244015000 Gasket M10 8 14 648910602080 Over Cover 1 15a 65023333000 Variable Speed 1 5 HP Motor 1 15b 65023337000 Variable Speed 3 HP Motor 1 16 65225008000 Screw 3 8 16 UNC 50 8mm 4 17 648912301080 Supporti...

Страница 7: ...erate a permanent alarm and have to be manually reset OVERHEAT ALERT If the drive temperature gets over 103 Degrees Fahrenheit the pump will slowly reduce speed until the temperature condition clears OVER CURRENT Indicates that the drive is overloaded or the motor has an electrical problem Once the over current condition clears the drive will restart OVER VOLTAGE Indicates excessive supply voltage...

Страница 8: ...as a result of freezing negligence improper installation use or care shall be replaced at our option without charge within 90 days of the receipt of defective product barring unforeseen delays After 90 days to obtain warranty replacements defective components should be returned transportation paid to the place of purchase For further Doheny s service contact Doheny s cus tomer care department No r...

Отзывы: