OPERATING AND SAFETY INSTRUCTIONS

Please follow the given instructions for use of the instrument because this will
guarantee correct instrument operation. Due to the fact that these instructions touch
on Product Liability, it is absolutely imperative that they be read carefully. Any claim
for defect will be rejected if one or more of the items was observed. Disregard of the
instructions can endanger warranty.

 

The instrument may only be used for the purpose described in this operating
manual. Due to safety reasons, the instrument must never be used for other
purposes not described in this manual. If you are not sure about the intended
purpose of the instrument please contact an expert.

 

The instrument has to be shipped only in the original packaging. Any instruments
shipped to us for return, exchange, warranty repair, update or examination must
be in their original packaging! Any other deliveries will be rejected. Therefore, you
should keep the original packaging and the technical documentation.

 

The instrument may only be operated with the voltage written on the power input
on the rear panel. Before opening the case disconnect the power plug.

 

Every modification has to be carried out only at the manufacturer or an authorized
service company. Any modification not released by the manufacturer leads to the
extinction of the operation permission.

 

With the introduction of a third person the warranty will be lost. In case of a
destroyed warranty seal, any warranty claim will be rejected.

 

The instrument must never be operated outdoors but only in dry, closed rooms.
Never use the instrument in a humid or wet environment nor near inflammables.

 

No liquids or conducting materials must get into the instrument. If this should
happen the instrument must be disconnected from power immediately and be
examined, cleaned and eventually be repaired by a qualified person.

 

Never subject the instrument to temperatures above +50

°

C or below -10

°

C.

Before operation the instrument should have a temperature of at least 10

°

C. Do

not place the instrument into direct sun light. Do not install the instrument near
heat sources.

 

Keep the top side of the instrument free in order to guarantee proper ventilation,
otherwise the instrument could be overheated. Never place heavy objects on the
instrument.

 

All cables connected with the instrument must be checked periodically. If there is
any damage the cables must be repaired or replaced by an authorized person.

 

Transport the instrument carefully, never let it fall or overturn. Make sure that
during transport and in use the instrument has a proper stand and does not fall,
slip or turn over because persons could be injured.

 

Never use the instrument in the immediate proximity of interfering electronic
devices (e.g. monitors, computers) since this could create disturbances within the
instrument and corrupt memory data.

 

The exchange of electronic parts (e.g. EPROMs for software update) is allowed
only if the instrument is disconnected from power supply.

 

When using the instrument in Germany, the appropriate VDE standards must be
followed. The following standards are of special importance: DIN VDE 0100 (Teil
300/11.85, Teil 410/11.83, Teil 481/10.87), DIN VDE 0532 (Teil 1/03.82), DIN
VDE 0550 (Teil 1/12.69), DIN VDE 0551 (05.72), DIN VDE 0551e (06.75), DIN
VDE 0700 (Teil 1/02.81, Teil 207/10.82), DIN VDE 0711 (Teil 500/10.89), DIN
VDE 0860 (05.89), DIN VDE 0869 (01.85). VDE papers can be obtained from the
VDE-Verlag GmbH, Berlin.

Содержание A-100CGK

Страница 1: ...DOEPFER CV Gate Keyboard CV Gate Keyboard CV Gate Keyboard CV Gate Keyboard A 100CGK A 100CGK A 100CGK A 100CGK User s Guide www doepfer com...

Страница 2: ...ronment nor near inflammables No liquids or conducting materials must get into the instrument If this should happen the instrument must be disconnected from power immediately and be examined cleaned a...

Страница 3: ...the Fatar website www fatar com All Fatar keybeds with up to 5 octaves can be combined with the A 100CGK OEM kit longer keybed are not possible These are the most important features of the A 100CGK re...

Страница 4: ...de is selected if the up or down button is held down during power on o keybed type 2 3 4 5 octaves necessary for transpose and offset options has to be set to 4 for the ready built version o transpose...

Страница 5: ...as well as a minimum current of 250mA The correct polarity of the DC voltage connector is outside ring GND inside lead 7 12V An external power supply of high quality and safety should be used The A 10...

Страница 6: ...A 170 A 171 to obtain a slowly increasing or decreasing control voltage that can be used to control other modules e g the frequency of a VCLFO A 147 or the amplification of a VCA A 130 131 132 to obt...

Страница 7: ...right panning A 134 or to control any other voltage controlled parameter of an A 100 module CV3 This 3 5 mm jack socket is the control voltage output of the A 100CGK that is controlled by the after t...

Страница 8: ...polarity or does not work Controls Display 3 digit LED display Six buttons with corresponding LEDs four to select a menu MODE TRANSP RETRIG HOLD two as up down buttons UP DOWN A menu is activated by...

Страница 9: ...ctaves keyboard 0 to 12 same as described above 5 octaves keyboard no transposition possible The reason for the different transpose ranges is the voltage range of CV1 0 5V This corresponds to 5 octave...

Страница 10: ...has to be chosen 2 3 4 or 5 This adjustment is necessary to select the correct note offset and to limit the transpose range for different keyboards The factory setting is 4 TRANSP This configuration m...

Страница 11: ...adjusted parameters in the configuration mode are valid i e number of octaves of the keyboard transpose type and gate polarity Extent of delivery The A 100CGK delivery contains the following parts 1...

Страница 12: ...008 by Doepfer Musikelektronik GmbH Geigerstr 13 82166 Graefelfing Germany Phone 49 89 89809510 Fax 49 89 89809511 Web Site www doepfer de Email sales doepfer de Doepfer Musikelektronik www doepfer co...

Отзывы: